On Sat, 17 Jul 2004 10:30:16 -0500, Bob Miller
wrote:

I'd like to enhance the pipe with a few buried radials. I happen to
have a 500' roll of 14-guage stranded *insulated* copper wire. Will
the insulation keep the wire from becoming "one with the dirt"?

Or should I go buy some bare solid copper wire?


Hi Bob,

Insulated will make a poor 60Hz safety ground (which you should
connect this ground to anyway). Insulated wire will make a perfectly
good RF ground (upwards to 5 orders of magnitude frequency shift makes
a considerable difference in what ground "means"). The pipe, on the
other hand, serves very little purpose. It is inadequate for a safety
ground, and useless for RF and maybe just suitable for providing a
mast base. It does give you a physical reference point - kinda like a
big solder lug.

Use up all your wire and enjoy - another 500 or 5000 feet won't bring
as much return as the first 500. For radials, try 10 X 50 feet, or 50
X 10 feet or something in between.