Thank you very much! I went through this alignment procedure and everything
is fine now. I needed to replace the 4569 divider chip on the display board
before I could do the alignment. This chip had a thermal
problem..........after 15 minutes of operation, the BFO injection frequency
would shift about 3kHz. After replacing the chip and going through the
alignment sequency, I have a good HF-150. Thanks again!
Pete
"arniek" wrote in message
...
Hello Pete,
alignment instructions for the reference oscillator:
-With the TEST message displayed, press the MODE button. Connect a
frequency counter to TP2 (Local Osc).
-Adjust TC1 (on the control unit) for a reading of 45.00000 MHz +/- 20 Hz
alignment instructions for the heterodyne oscillator:
-With the TEST message displayed, connect a frequency counter to TP6
(Audio)
-Press the MODE button. Adjust TC2 for a reading of 3234 Hz +/- 10 Hz.
-Press the FAST button. Adjust VR1 for a reading 8 Hz above (3242 Hz)
-Repeat the procedure
My HF-150 (built around 1995) works very well after repeating that
alignment procedure a few times.
73
Arnie
|