In article ,
xpyttl wrote:
"JE" wrote in message
...
Anyone know if these NTE7164 is a drop in replacement for NE602?
What are other current IC's being used for mixers by homebrewers?
NE602, NE612, SA602, SA612 all virtually identical. NE/SA are different
manufacturers,
No, NE and SA are both Philips prefixes, but different temperature
ratings. NE is the commercial range of 0 to +70 deg C, SA the
mil/industrial range of -40 to +85 deg C.
602/612 are different test specs. Generally the 612s are a
little cheaper. Same basic specs just tested less extensively.
Mark Zenier
Googleproofaddress(account:mzenier provider:eskimo domain:com)