View Single Post
  #2   Report Post  
Old February 20th 06, 07:11 AM
F6AOJ F6AOJ is offline
Junior Member
 
First recorded activity by RadioBanter: Feb 2006
Posts: 4
Send a message via Skype™ to F6AOJ
Default

hope it will be usefull to you

gnd pulse on control position
reset previous position and indicator
and set new position
latched position is confirmed by indicator

Loral 063-B237-B2C-7A1

RF connector N
position Nr 6
Vdc 24
ctrl connector Mil 14-15 15 pins


A +24v
B out1
C out2
D out3
E out4
F out5
G out6

J indicator 1
K indicator 2
L indicator 3
M indicator 4
N indicator 5
H indicator 6
P com indicator

R nc

73 Jeff F6AOJ



Quote:
Originally Posted by Joe Curry
I have just come into possession of a Loral RF switch. It is a SP3T variety
with N-connectors. It also has a make MIL circular connector (14-15) for the
power and indicator connections.

The part number is 9033-D239-D2D-7A2.

I have Googled ad nauseum without results. Does anyone have any information
on the wiring connections and/or the specs?

Thanks for your help and 73,

Joe
K3ICO