View Single Post
  #3   Report Post  
Old April 13th 07, 03:32 PM posted to rec.radio.amateur.boatanchors
Scott Dorsey Scott Dorsey is offline
external usenet poster
 
First recorded activity by RadioBanter: Jul 2006
Posts: 774
Default Ranger Blowing 5A fuse?

NoMoreSpam wrote:
wb5kcm wrote:
My Ranger is still every once in a while blowing the 5 amp primary
fuse when I switch it on. I have checked everything for a possible
intermittent short and everything checks good. The only thing I can
think of is inrush current. My Ranger has all the mods in the power
supply, solid state both HV and LV. The LV capacitor is 330 mfd and
the HV cap is 165 mfd. I did not suspect inrush current with the choke
input filters but I suspect with the solid state rectifiers and the
additional capacitor size this is possible? Does anyone have any
recommendations on a method to limit inrush? Also, does anyone know
what the nominal current consumption from the 115 VAC line with full
output/modulation for the Ranger? Any info is appreciated.
73, Randy

Very possible that the meter switch is intermittently arcing, causing the fuse
to blow. I ended up having to replace my meter switch, which cured the problem.


WHEN is the fuse blowing?

If it's blowing at times other than initial turn-on, it's not an inrush
current issue.
--scott
--
"C'est un Nagra. C'est suisse, et tres, tres precis."