Hammarlund HQ-180A
Hello Roger:
I expect the selectivity is too narrow because of the regeneration.
Regeneration also increases the gain. It may need to be realigned
according to the manual - but I would not do that until you find the cause
of the regeneration.
It could be a tube, but more likely it is a defective bypass - either in the
plate/screen leads to the if stage or the grid bypass. Since all of these
caps are ceramic disc caps, they should still be good.
Start with the simple stuff and measure the voltage and resistance as
specified in the manual, on the if stages.
Remember to find the problem before alignment.
Colin K7FM
|