The question is, is there a way to come up w/ a rough estimate of the mix
value? I wound some test coils and come up w/ these figures:
T-50 15turns 30awg = ~150uH
T-37 9turns 30awg = ~180uH
Perhaps there is a chart or something similar somewhere that I have
overlooked that will give me an idea.
The equation goes;
Turns = 100SQR(uH/Al) where Al is the inductance in uH per 100 turns)
and
15 = 100SQR(150/Al)
and (0.15)^2 = 150/Al
and
150/0.0225 = Al = 6666.
You have ferrite not powdered iron.
For Ferrite, it's just the conversion
Turns = 1000SQR (mH/Al) where Al = mH/1000 turns
15 = 1000SQR(.15/Al)
and
0.15/0.00225 =66 which looks like, (for T50 core) material 61
W4ZCB
|