Yesterday I came across an example where thinking went astray.
My Runco three large CRT projector failed and I traced it to the first power supply of all things. There were four square power resisters, two in series but what hit me in the head was that the draftsman had put these resisters in a tight touching square Now you must know that you add a fudge factor to the power level but you never cancel it by removing circulation. They didn't have the apearance of damage but I took them out anyway. True enough two in parallel had blown and the engineer probably asked for them to be in parallel to provide the required surface area. I replaced them with tubular hollow wre wounds with separation. To many it is only obvious after the fact or shall I call them monday morning quarter backs. I will see the superbowl in my home theatre with a grin on my face Art |
#2
![]() |
|||
|
|||
![]()
art wrote:
Yesterday I came across an example where thinking went astray. My Runco three large CRT projector failed and I traced it to the first power supply of all things. There were four square power resisters, two in series but what hit me in the head was that the draftsman had put these resisters in a tight touching square Now you must know that you add a fudge factor to the power level but you never cancel it by removing circulation. They didn't have the apearance of damage but I took them out anyway. True enough two in parallel had blown and the engineer probably asked for them to be in parallel to provide the required surface area. I replaced them with tubular hollow wre wounds with separation. To many it is only obvious after the fact or shall I call them monday morning quarter backs. I will see the superbowl in my home theatre with a grin on my face Art How many hours did you have on this projector at failure? Part of engineering a design is lifetime expectancy, judging by the projectors I've seen over the past few years a three CRT projector has exceeded it's expected lifetime. |
#3
![]() |
|||
|
|||
![]() "gwatts" wrote in message ... art wrote: Yesterday I came across an example where thinking went astray. My Runco three large CRT projector failed and I traced it to the first power supply of all things. There were four square power resisters, two in series but what hit me in the head was that the draftsman had put these resisters in a tight touching square Now you must know that you add a fudge factor to the power level but you never cancel it by removing circulation. They didn't have the apearance of damage but I took them out anyway. True enough two in parallel had blown and the engineer probably asked for them to be in parallel to provide the required surface area. I replaced them with tubular hollow wre wounds with separation. To many it is only obvious after the fact or shall I call them monday morning quarter backs. I will see the superbowl in my home theatre with a grin on my face Art How many hours did you have on this projector at failure? Part of engineering a design is lifetime expectancy, judging by the projectors I've seen over the past few years a three CRT projector has exceeded it's expected lifetime. Yes these are begining to show up in Goodwill stores. |
#4
![]() |
|||
|
|||
![]()
I agree, my 8 inch CRTs have very little hours on them tho I am always
looking for spare tubes. I mentioned it to Curt who fixes them and he stated it is not the first time he has seen power resisters blow in the supply. Manufacturers don't want to add a lot of fans because of the noise. Similar things happen with the Hitachi rear projection t.v.s maybe that's why so many are failing. The idea of using two power resisters in parallel instead of just one of a lower value is purely to take advantage of the increased surface area, in this case the problem excabated because the resistors were of the square form so the draftsman probably placed the four in a tight touching square for neatness which retarded circulation.i The hollow ohmites that I put in should solve that oversight. The 8 inch crt forms were made by an unknown company in Japan for Zenith who then supplied them to G.E., nec and Runco for relabeling so it may well be a one type set thing ..Have a single lamp projector of Runco but liquid spilt on the power supply and burnt the traces as well. Do you have the schematic? By the way the 8 inch crt are underdriven which is a huge advantage in terms of life. The early forms were over driven which forced designers to go back to the 7 inch forms and below in the case of rear projection to accomplish better life. By the way on single lamp incandescent projector forms I replace the inside bulb when they fail and use a wire clip to hold it in, much cheaper than paying a few hundred dollars to replace. I would expect that the new rear projection lights on the new tvs would benefit from the same treatment.. I do have a lot of fun playing around with things to retard the oncomming old age. Art gwatts wrote: art wrote: Yesterday I came across an example where thinking went astray. My Runco three large CRT projector failed and I traced it to the first power supply of all things. There were four square power resisters, two in series but what hit me in the head was that the draftsman had put these resisters in a tight touching square Now you must know that you add a fudge factor to the power level but you never cancel it by removing circulation. They didn't have the apearance of damage but I took them out anyway. True enough two in parallel had blown and the engineer probably asked for them to be in parallel to provide the required surface area. I replaced them with tubular hollow wre wounds with separation. To many it is only obvious after the fact or shall I call them monday morning quarter backs. I will see the superbowl in my home theatre with a grin on my face Art How many hours did you have on this projector at failure? Part of engineering a design is lifetime expectancy, judging by the projectors I've seen over the past few years a three CRT projector has exceeded it's expected lifetime. |
#5
![]() |
|||
|
|||
![]() "art" wrote in message ups.com... I agree, my 8 inch CRTs have very little hours on them tho I am always looking for spare tubes. I mentioned it to Curt who fixes them and he stated it is not the first time he has seen power resisters blow in the supply. Manufacturers don't want to add a lot of fans because of the noise. Similar things happen with the Hitachi rear projection t.v.s maybe that's why so many are failing. The idea of using two power resisters in parallel instead of just one of a lower value is purely to take advantage of the increased surface area, in this case the problem excabated because the resistors were of the square form so the draftsman probably placed the four in a tight touching square for neatness which retarded circulation.i The hollow ohmites that I put in should solve that oversight. The 8 inch crt forms were made by an unknown company in Japan for Zenith who then supplied them to G.E., nec and Runco for relabeling so it may well be a one type set thing .Have a single lamp projector of Runco but liquid spilt on the power supply and burnt the traces as well. Do you have the schematic? By the way the 8 inch crt are underdriven which is a huge advantage in terms of life. The early forms were over driven which forced designers to go back to the 7 inch forms and below in the case of rear projection to accomplish better life. By the way on single lamp incandescent projector forms I replace the inside bulb when they fail and use a wire clip to hold it in, much cheaper than paying a few hundred dollars to replace. I would expect that the new rear projection lights on the new tvs would benefit from the same treatment.. I do have a lot of fun playing around with things to retard the oncomming old age. Art gwatts wrote: art wrote: Yesterday I came across an example where thinking went astray. My Runco three large CRT projector failed and I traced it to the first power supply of all things. There were four square power resisters, two in series but what hit me in the head was that the draftsman had put these resisters in a tight touching square Now you must know that you add a fudge factor to the power level but you never cancel it by removing circulation. They didn't have the apearance of damage but I took them out anyway. True enough two in parallel had blown and the engineer probably asked for them to be in parallel to provide the required surface area. I replaced them with tubular hollow wre wounds with separation. To many it is only obvious after the fact or shall I call them monday morning quarter backs. I will see the superbowl in my home theatre with a grin on my face Art How many hours did you have on this projector at failure? Part of engineering a design is lifetime expectancy, judging by the projectors I've seen over the past few years a three CRT projector has exceeded it's expected lifetime. Doubt if it was a fault in engineering. If the engineers had their way it would probably be a dale heatsinked to the chassis.Often one engineering team designs it and another goes through to find out how they can cut corners. |
#6
![]() |
|||
|
|||
![]() On 23 Jan, 14:49, "Jimmie D" wrote: "art" wrote in oglegroups.com... I agree, my 8 inch CRTs have very little hours on them tho I am always looking for spare tubes. I mentioned it to Curt who fixes them and he stated it is not the first time he has seen power resisters blow in the supply. Manufacturers don't want to add a lot of fans because of the noise. Similar things happen with the Hitachi rear projection t.v.s maybe that's why so many are failing. The idea of using two power resisters in parallel instead of just one of a lower value is purely to take advantage of the increased surface area, in this case the problem excabated because the resistors were of the square form so the draftsman probably placed the four in a tight touching square for neatness which retarded circulation.i The hollow ohmites that I put in should solve that oversight. The 8 inch crt forms were made by an unknown company in Japan for Zenith who then supplied them to G.E., nec and Runco for relabeling so it may well be a one type set thing .Have a single lamp projector of Runco but liquid spilt on the power supply and burnt the traces as well. Do you have the schematic? By the way the 8 inch crt are underdriven which is a huge advantage in terms of life. The early forms were over driven which forced designers to go back to the 7 inch forms and below in the case of rear projection to accomplish better life. By the way on single lamp incandescent projector forms I replace the inside bulb when they fail and use a wire clip to hold it in, much cheaper than paying a few hundred dollars to replace. I would expect that the new rear projection lights on the new tvs would benefit from the same treatment.. I do have a lot of fun playing around with things to retard the oncomming old age. Art gwatts wrote: art wrote: Yesterday I came across an example where thinking went astray. My Runco three large CRT projector failed and I traced it to the first power supply of all things. There were four square power resisters, two in series but what hit me in the head was that the draftsman had put these resisters in a tight touching square Now you must know that you add a fudge factor to the power level but you never cancel it by removing circulation. They didn't have the apearance of damage but I took them out anyway. True enough two in parallel had blown and the engineer probably asked for them to be in parallel to provide the required surface area. I replaced them with tubular hollow wre wounds with separation. To many it is only obvious after the fact or shall I call them monday morning quarter backs. I will see the superbowl in my home theatre with a grin on my face Art How many hours did you have on this projector at failure? Part of engineering a design is lifetime expectancy, judging by the projectors I've seen over the past few years a three CRT projector has exceeded it's expected lifetime.Doubt if it was a fault in engineering. If the engineers had their way it would probably be a dale heatsinked to the chassis.Often one engineering team designs it and another goes through to find out how they can cut corners.- Hide quoted text -- Show quoted text - |
#7
![]() |
|||
|
|||
![]() On 23 Jan, 14:49, "Jimmie D" wrote: "art" wrote in oglegroups.com... snipurs did you have on this projector at failure? Part of engineering a design is lifetime expectancy, judging by the projectors I've seen over the past few years a three CRT projector has exceeded it's expected lifetime.Doubt if it was a fault in engineering. If the engineers had their way it would probably be a dale heatsinked to the chassis.Often one engineering team designs it and another goes through to find out how they can cut corners.- Hide quoted text -- Show quoted text - Jimmy it is rare to use two resisters instead of one because a board becomes bigger and introduces cost. When you get to power resisters it is not unusual to place two in parallel and accept the cost. In this case a cost improver would try to make the case for one single resister instead of four since a Dale with heatsink would be comparitively prohibative. The engineers calculation for wattage may well have been correct without being side blinded by the fact of some square form resisters. Art |
#8
![]() |
|||
|
|||
![]() "art" wrote in message oups.com... On 23 Jan, 14:49, "Jimmie D" wrote: "art" wrote in oglegroups.com... snipurs did you have on this projector at failure? Part of engineering a design is lifetime expectancy, judging by the projectors I've seen over the past few years a three CRT projector has exceeded it's expected lifetime.Doubt if it was a fault in engineering. If the engineers had their way it would probably be a dale heatsinked to the chassis.Often one engineering team designs it and another goes through to find out how they can cut corners.- Hide quoted text -- Show quoted text - Jimmy it is rare to use two resisters instead of one because a board becomes bigger and introduces cost. When you get to power resisters it is not unusual to place two in parallel and accept the cost. In this case a cost improver would try to make the case for one single resister instead of four since a Dale with heatsink would be comparitively prohibative. The engineers calculation for wattage may well have been correct without being side blinded by the fact of some square form resisters. Art Depends on the cost of the resistors. Prices seem to increase somewhat expotentially with wattage so the two smaller ones may have been cheaper than one larger. In this case the cost improver would have went for the multiple resistors. |
#9
![]() |
|||
|
|||
![]()
art wrote:
On 23 Jan, 14:49, "Jimmie D" wrote: "art" wrote in oglegroups.com... ...Part of engineering a design is lifetime expectancy... ...Doubt if it was a fault in engineering. If the engineers had their way it would probably be a dale heatsinked to the chassis.Often one engineering team designs it and another goes through to find out how they can cut corners. Jimmy it is rare to use two resisters instead of one because a board becomes bigger and introduces cost. If they used one resistor in another place or places it's could have been easier to use multiples in series/parallel where they could rather than purchase and stock another value at the factory. I worked at a place where we used 5532 op amps in many audio circuits and in one place as a flip flop so we wouldn't have to stock a 74xx or 40xx just for that one use. It was easier on the assemblers to have one bin of chips, better quantity pricing, no sweating running out of one part kept in smaller quantity, (insert more bean counter stuff...) |
#10
![]() |
|||
|
|||
![]() On 23 Jan, 18:14, gwatts wrote: art wrote: On 23 Jan, 14:49, "Jimmie D" wrote: "art" wrote in oglegroups.com... ...Part of snip where we used 5532 op amps in many audio circuits and in one place as a flip flop so we wouldn't have to stock a 74xx or 40xx just for that one use. It was easier on the assemblers to have one bin of chips, better quantity pricing, no sweating running out of one part kept in smaller quantity, (insert more bean counter stuff...) Very interesting if you are refering to power resisters used in a non switching power supply. In my case I have had no experience of seeing power supplies with excess resisters or with the use of dale prescision resisters or resisters mounted on a heat sink which is fortunate for me otherwise I would never have resolved my particular problem It would appear that I retired just in time before engineering studies became out of fashion Happy trails Art |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
thinking about some new gear | Shortwave | |||
Intuitively {To My Way of Thinking} for an In-the-Attic Antenna the Horizontal [Flat] Loop Antenna offers these Benefits : | Shortwave | |||
Thinking about buying a Satellit 800... | Shortwave | |||
Thinking about buying a Satellit 800... | Shortwave | |||
Thinking about a wideband receiver... | Shortwave |