Reply
 
LinkBack Thread Tools Search this Thread Display Modes
  #1   Report Post  
Old May 12th 07, 11:01 AM posted to rec.radio.amateur.boatanchors
external usenet poster
 
First recorded activity by RadioBanter: Jun 2006
Posts: 395
Default BC-453 H.V.

Does anybody know which is the nominal H.V. delivered by the BC-453 dynamotor?

Thanks and 73

Tony I0JX
  #2   Report Post  
Old May 12th 07, 04:41 PM posted to rec.radio.amateur.boatanchors
external usenet poster
 
First recorded activity by RadioBanter: Jul 2006
Posts: 241
Default BC-453 H.V.

I think the DM-32A was the designated dynamotor for the BC-453. The design
output was 250 volts at .05 amps with 28 volts input. In conversions, the
DM-32 could be used for powering it, as it had 12 volts input and the same
output.

73, Colin K7FM


  #3   Report Post  
Old May 12th 07, 05:27 PM posted to rec.radio.amateur.boatanchors
external usenet poster
 
First recorded activity by RadioBanter: Jul 2006
Posts: 70
Default BC-453 H.V.

A listing on Ebay shows the input at 28VDC and the output as 250VDC.

Dick

On Sat, 12 May 2007 11:01:30 +0200, "Antonio Vernucci"
wrote:

Does anybody know which is the nominal H.V. delivered by the BC-453 dynamotor?

Thanks and 73

Tony I0JX



--
Posted via a free Usenet account from http://www.teranews.com

  #4   Report Post  
Old May 12th 07, 06:56 PM posted to rec.radio.amateur.boatanchors
external usenet poster
 
First recorded activity by RadioBanter: Jun 2006
Posts: 395
Default BC-453 H.V.

Thanks for answers

Tony I0JX
  #5   Report Post  
Old May 16th 07, 12:54 PM posted to rec.radio.amateur.boatanchors
external usenet poster
 
First recorded activity by RadioBanter: Feb 2007
Posts: 41
Default BC-453 H.V.

On May 12, 7:56 pm, "Antonio Vernucci" wrote:
Thanks for answers

Tony I0JX


But I've also read that the variuos 'command' receivers (BC453, 454
etc,) will work well with much lower B+ voltages.
Which are much kinder on the 60 year old decoupling capacitors etc.
can't remember the value but could it have been as low as 120 volts
DC?
Cos it occurs to me that one could use a 150 volt gas regulator tube
(OD3?) on the output of a power supply to achieve that?



  #6   Report Post  
Old May 16th 07, 03:24 PM posted to rec.radio.amateur.boatanchors
external usenet poster
 
First recorded activity by RadioBanter: Jul 2006
Posts: 322
Default BC-453 H.V.

terryS ) writes:
On May 12, 7:56 pm, "Antonio Vernucci" wrote:
Thanks for answers

Tony I0JX


But I've also read that the variuos 'command' receivers (BC453, 454
etc,) will work well with much lower B+ voltages.
Which are much kinder on the 60 year old decoupling capacitors etc.
can't remember the value but could it have been as low as 120 volts
DC?


I can't say that I've seen that applied to Command sets specifically,
but it's not an unknown concept.

IN 1970, there was a two-part article by Fred Brown about updating an
HRO receiver. He replaced the full size tubes with more modern
equivalents, did some other changes, and ran it at a lower voltage than
originally. He gave all kinds of reasons for the lower plate voltage,
and mentioned that the Collins S-line receiver used lower plate voltage.

I think it was that article where he said the only disadvantage was lower
audio output.

Michael VE2BVW


Cos it occurs to me that one could use a 150 volt gas regulator tube
(OD3?) on the output of a power supply to achieve that?



  #7   Report Post  
Old May 16th 07, 04:05 PM posted to rec.radio.amateur.boatanchors
external usenet poster
 
First recorded activity by RadioBanter: Jul 2006
Posts: 774
Default BC-453 H.V.

terryS wrote:

But I've also read that the variuos 'command' receivers (BC453, 454
etc,) will work well with much lower B+ voltages.
Which are much kinder on the 60 year old decoupling capacitors etc.
can't remember the value but could it have been as low as 120 volts
DC?
Cos it occurs to me that one could use a 150 volt gas regulator tube
(OD3?) on the output of a power supply to achieve that?


You might be able to do a shunt regulator, since the current demands are
small. Be more reliable to use a solid-state series regulator made with
a zener diode string and a TIP50 darlington. You could use an OD3 and a
6L6, though, I think.

But, since you're going to be running the things on AC house current
anyway rather than on the original dynamotors in most installations,
it would be easier just to use an inexpensive 120V isolation transformer
driving a bridge rectifier and a pi filter as your power supply. Cheaper
to build than a high voltage supply and you get 168V out of it minus the
loss in the filter choke.
--scott
--
"C'est un Nagra. C'est suisse, et tres, tres precis."
  #8   Report Post  
Old May 16th 07, 06:04 PM posted to rec.radio.amateur.boatanchors
external usenet poster
 
First recorded activity by RadioBanter: Apr 2007
Posts: 88
Default BC-453 H.V.

Michael Black wrote:


IN 1970, there was a two-part article by Fred Brown about updating an
HRO receiver. He replaced the full size tubes with more modern
equivalents, did some other changes, and ran it at a lower voltage than
originally. He gave all kinds of reasons for the lower plate voltage,
and mentioned that the Collins S-line receiver used lower plate voltage.


I recall that at the HAMfest at Birmingham (AL) several years ago
(possibly as many as 15) some chap had a BC-348 that he had converted to
solid state. All of the tubes had been replaced by transistors - and it
worked pretty well - at least there in the Jefferson Convention Center.

I've thought about trying the same with one of the arc5 receivers - just
never got around to it. Dave Stinson would probably be one to ask about
such a project - Dave- got your ears on?

best regards...
--
randy guttery

A Tender Tale - a page dedicated to those Ships and Crews
so vital to the United States Silent Service:
http://tendertale.com
  #9   Report Post  
Old May 16th 07, 06:30 PM posted to rec.radio.amateur.boatanchors
external usenet poster
 
First recorded activity by RadioBanter: Apr 2007
Posts: 23
Default BC-453 H.V.


On 16-May-2007, (Scott Dorsey) wrote:

terryS wrote:

But I've also read that the variuos 'command' receivers (BC453, 454
etc,) will work well with much lower B+ voltages.
Which are much kinder on the 60 year old decoupling capacitors etc.
can't remember the value but could it have been as low as 120 volts
DC?
Cos it occurs to me that one could use a 150 volt gas regulator tube
(OD3?) on the output of a power supply to achieve that?


You might be able to do a shunt regulator, since the current demands are
small. Be more reliable to use a solid-state series regulator made with
a zener diode string and a TIP50 darlington. You could use an OD3 and a
6L6, though, I think.

But, since you're going to be running the things on AC house current
anyway rather than on the original dynamotors in most installations,
it would be easier just to use an inexpensive 120V isolation transformer
driving a bridge rectifier and a pi filter as your power supply. Cheaper
to build than a high voltage supply and you get 168V out of it minus the
loss in the filter choke.
--scott
--
"C'est un Nagra. C'est suisse, et tres, tres precis."


Back in the 1950s, we ran the ARC-5 receivers on AC-DC transformerless power supplies from 115 VAC.
I think you had to change the filaments to series and use a 35w4 rectifier. Also had to be careful
to plug into the AC so that the Neutral connected to the chassis. The B+ would be about 155 VDC.
Not Safe!

Ken Fowler
  #10   Report Post  
Old May 16th 07, 07:05 PM posted to rec.radio.amateur.boatanchors
external usenet poster
 
First recorded activity by RadioBanter: Jul 2006
Posts: 322
Default BC-453 H.V.

Randy or Sherry Guttery ) writes:
Michael Black wrote:


IN 1970, there was a two-part article by Fred Brown about updating an
HRO receiver. He replaced the full size tubes with more modern
equivalents, did some other changes, and ran it at a lower voltage than
originally. He gave all kinds of reasons for the lower plate voltage,
and mentioned that the Collins S-line receiver used lower plate voltage.


I recall that at the HAMfest at Birmingham (AL) several years ago
(possibly as many as 15) some chap had a BC-348 that he had converted to
solid state. All of the tubes had been replaced by transistors - and it
worked pretty well - at least there in the Jefferson Convention Center.

Hank Cross, W1OOP, had an article in Ham Radio magazine in 1969 about
converting one to solid state. It's always interesting how that sort
of conversion went, becuase different people had different philosophy.
Some try to make universal type solid state "tubes". Others build
modules that fit the specific tube socket, but don't tamper with the
existing circuitry. Others, made modules but did do some fiddling
with the existing values.

Hank Cross's philosophy was to basically treat it as a chassis
with coils and capacitors, and hence wasn't stuck with trying to retro
fit solid state devices. It was a mixture of mosfets, bipolar transistors
and ICs. Of course, he also used the opportunity to add some things
he felt missing, like an FM detector (he did a lot of VHF work) and
I think he even made it double conversion.

Michael VE2BVW

I've thought about trying the same with one of the arc5 receivers - just
never got around to it. Dave Stinson would probably be one to ask about
such a project - Dave- got your ears on?

best regards...
--
randy guttery

A Tender Tale - a page dedicated to those Ships and Crews
so vital to the United States Silent Service:
http://tendertale.com



Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On



All times are GMT +1. The time now is 06:24 PM.

Powered by vBulletin® Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.
Copyright ©2004-2025 RadioBanter.
The comments are property of their posters.
 

About Us

"It's about Radio"

 

Copyright © 2017