Reply
 
LinkBack Thread Tools Search this Thread Display Modes
  #1   Report Post  
Old November 23rd 04, 01:38 PM
zindazenda
 
Posts: n/a
Default Slighty faulty HP141t question

hello...

my old but trusty hp141t (1.2ghz) appears to have developed a fault/out of
calibration??

it all works but now there is a spurious reading (peak) about 6.5mhz down
from the fundamental peak..about 55db down..its always there when a signal
is present (but not of course when no input.)
It's defiantly the analyser as I have tried different tx sources and its
always present..
sniffing rf via bird 43 attenuator..

Any ideas??

simon g0zen


  #2   Report Post  
Old November 23rd 04, 08:48 PM
Gary Schafer
 
Posts: n/a
Default

When you switch in an extra 10 db of attenuation at the input, does
the spur drop 10 db as well as the wanted signal drop 10 db?
If spur drops more then IM is being generated in the analyzer from
overload possibly.

73
Gary K4FMX


On Tue, 23 Nov 2004 12:38:05 -0000, "zindazenda"
wrote:

hello...

my old but trusty hp141t (1.2ghz) appears to have developed a fault/out of
calibration??

it all works but now there is a spurious reading (peak) about 6.5mhz down
from the fundamental peak..about 55db down..its always there when a signal
is present (but not of course when no input.)
It's defiantly the analyser as I have tried different tx sources and its
always present..
sniffing rf via bird 43 attenuator..

Any ideas??

simon g0zen


  #3   Report Post  
Old November 24th 04, 10:45 PM
zindazenda
 
Posts: n/a
Default

yes it seems to drop 10db as well...its possible to "remove" the spur by
switching in more attenuation, but doing this completly removes the 2nd/3rd
harmonics as well..which is after all what I am trying to look at..

oh the plug ins are 8552a and 8554b

simon
"Gary Schafer" wrote in message
...
When you switch in an extra 10 db of attenuation at the input, does
the spur drop 10 db as well as the wanted signal drop 10 db?
If spur drops more then IM is being generated in the analyzer from
overload possibly.

73
Gary K4FMX


On Tue, 23 Nov 2004 12:38:05 -0000, "zindazenda"
wrote:

hello...

my old but trusty hp141t (1.2ghz) appears to have developed a fault/out

of
calibration??

it all works but now there is a spurious reading (peak) about 6.5mhz down
from the fundamental peak..about 55db down..its always there when a

signal
is present (but not of course when no input.)
It's defiantly the analyser as I have tried different tx sources and its
always present..
sniffing rf via bird 43 attenuator..

Any ideas??

simon g0zen




Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Noise and Loops Question Tony Angerame Antenna 4 August 24th 04 11:12 PM
transmitter question - its a dousy duckman Homebrew 24 January 3rd 04 01:11 AM
transmitter question - its a dousy duckman Homebrew 0 December 9th 03 12:51 AM
Seperation question???? thanks [email protected] Antenna 0 October 7th 03 08:57 PM
Question about attenuators ... Doug McLaren Antenna 2 August 31st 03 05:20 AM


All times are GMT +1. The time now is 02:44 AM.

Powered by vBulletin® Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.
Copyright ©2004-2025 RadioBanter.
The comments are property of their posters.
 

About Us

"It's about Radio"

 

Copyright © 2017