Any idea what this battery was used for? Found it at a flea market for $1.
The two-piece Bakelite case says The Bristol Company, Waterbury, Conn. Inside are two glass capsules with different stuff in the bottom. The bottom stuff in capsule looks like clay, the other looks like a ball of wrinkled foil. A sticker on the left capsule says the Eppley Laboratory, Newport, R.I. Both capsules still contain liquid. They are cushioned in a tidy little felt blanket. Phil "just curious" Nelson Phil's Old Radios http://antiqueradio.org/index.html |
#2
![]() |
|||
|
|||
![]()
In article ,
"Phil Nelson" wrote: Any idea what this battery was used for? Found it at a flea market for $1. The two-piece Bakelite case says The Bristol Company, Waterbury, Conn. Inside are two glass capsules with different stuff in the bottom. The bottom stuff in capsule looks like clay, the other looks like a ball of wrinkled foil. A sticker on the left capsule says the Eppley Laboratory, Newport, R.I. Both capsules still contain liquid. They are cushioned in a tidy little felt blanket. Phil "just curious" Nelson Phil's Old Radios http://antiqueradio.org/index.html --------------------------------------------------------------------- [Image] --------------------------------------------------------------------- [Image] It says right on it that it is a "Standard Cell". I believe "Standard Cells" are used for calibrating electrical instruments like voltmeters and etc. I also believe that they will be damaged by drawing current from them, so they must be used in special calibration circuits. Regards, John Byrns -- Surf my web pages at, http://fmamradios.com/ |
#3
![]() |
|||
|
|||
![]()
Phil,
See below. Dale [The "standard cell" is a saturated Weston cell, containing an electrode of mercury in contact with a paste of mercurous sulfate and an electrode of cadmium amalgam in contact with a saturated solution or cadmium sulfate. When little or no current is drawn from the cell, it produces a terminal voltage of long-term stability. The precise value for each cell is given on its label.] "Phil Nelson" wrote in message ... Any idea what this battery was used for? Found it at a flea market for $1. The two-piece Bakelite case says The Bristol Company, Waterbury, Conn. Inside are two glass capsules with different stuff in the bottom. The bottom stuff in capsule looks like clay, the other looks like a ball of wrinkled foil. A sticker on the left capsule says the Eppley Laboratory, Newport, R.I. Both capsules still contain liquid. They are cushioned in a tidy little felt blanket. Phil "just curious" Nelson Phil's Old Radios http://antiqueradio.org/index.html |
#4
![]() |
|||
|
|||
![]()
Sounds like a bingo. There is an old piece of tape on the side of the case
on which someone wrote "1.01998 volts," followed some other tiny scribbles which have been worn off. Phil "dale" wrote in message ... [The "standard cell" is a saturated Weston cell, containing an electrode of mercury in contact with a paste of mercurous sulfate and an electrode of cadmium amalgam in contact with a saturated solution or cadmium sulfate. When little or no current is drawn from the cell, it produces a terminal voltage of long-term stability. The precise value for each cell is given on its label.] |
#5
![]() |
|||
|
|||
![]()
I have two of them. The were indeed for verifying test equipment. Be fairly
careful with them, as they are old and becoming fragile. Use volt meter set on a scale that will allow you to see 1 volt or more. They also make great bookends, for light books.... p.s. I paid 50 cents apiece for mine.... bob in phx.... "Phil Nelson" wrote in message ... Sounds like a bingo. There is an old piece of tape on the side of the case on which someone wrote "1.01998 volts," followed some other tiny scribbles which have been worn off. Phil "dale" wrote in message ... [The "standard cell" is a saturated Weston cell, containing an electrode of mercury in contact with a paste of mercurous sulfate and an electrode of cadmium amalgam in contact with a saturated solution or cadmium sulfate. When little or no current is drawn from the cell, it produces a terminal voltage of long-term stability. The precise value for each cell is given on its label.] |
#6
![]() |
|||
|
|||
![]()
Phil Nelson wrote:
Any idea what this battery was used for? Found it at a flea market for $1. The two-piece Bakelite case says The Bristol Company, Waterbury, Conn. Inside are two glass capsules with different stuff in the bottom. The bottom stuff in capsule looks like clay, the other looks like a ball of wrinkled foil. A sticker on the left capsule says the Eppley Laboratory, Newport, R.I. Both capsules still contain liquid. They are cushioned in a tidy little felt blanket. Phil "just curious" Nelson Phil's Old Radios http://antiqueradio.org/index.html ------------------------------------------------------------------------ ------------------------------------------------------------------------ Ha! That inside view is exactly the picture in my old study books showing a standard voltage reference. It might even still work. If you want to test, use a high quality voltmeter, and check its voltage. DONT let it deliver any current, because it becomes useless rather quickly. In my book its called a WESTON ELEMENT, and used as a calibration standard(very expensive). On the plus site is mercury, covered with cadmium sulfate. On the minus site is mercury+12percent cadmium, also covered with cadmium sulfate. The fluid is water saturated with cadmium sulfate. The voltage should be 1.0183 volt at 20 degree Celcius.(68 F) The book is from 1958 ![]() |
#7
![]() |
|||
|
|||
![]() "Sjouke Burry" wrote in message ... The book is from 1958 ![]() You learn something new every day. I had never heard of these. Can anyone elaborate a bit on what exactly they were used in? Calibrating what, meters? |
#8
![]() |
|||
|
|||
![]()
Buck Frobisher wrote:
"Sjouke Burry" wrote in message ... The book is from 1958 ![]() You learn something new every day. I had never heard of these. Can anyone elaborate a bit on what exactly they were used in? Calibrating what, meters? Anyplace/time you needed an accurate voltage. In the lab you had very accurate resistor divider banks, where you reduced your test-voltage to the same voltage as the cell. That was tested with a very sensitive galvanometer, where, when the galvanometer indicated zero (micro)volt difference between the two, your testvoltage followed From: Vtest=bankratio X cellvoltage. In this way, at the moment of the readout, the cell did not supply any current, and thus the error was minimal. And yes, meter calibration,reference source calibration (current and voltage) were ever needed. And even to calibrate these reference cells, because due to impurities non of these cells had exactly the same voltage. Now, how to calibrate the first one? I have no idea, but in most countries you had a standards lab to do that for you. |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
fuel cell battery buffer or cap? | Antenna | |||
ans calculations/ fuel cell battery buffer or cap? | Policy | |||
Loose connection inside D cell battery | Homebrew | |||
Loose connection inside D cell battery | Homebrew | |||
Want gel cell battery | Swap |