  #1   Report Post  
Old October 31st 06, 11:45 PM posted to rec.radio.amateur.antenna
external usenet poster
 
First recorded activity by RadioBanter: Jul 2006
Posts: 702
Default guy wire for the ground wire

I don't recall seeing it anywhere, but is there any problem with using some
left over guy wire (3/16 EHS) to go from the tower to a ground rod at the
base of a tower. Planning on going to about 60 feet with Rohn 25 and will
probably use a ground rod at the tower and maybe one at each of the guy
points. Just seems to me that if the correct clamps are used the wires and
tower would be the same material and not have a galvonic reaction.


  #2   Report Post  
Old November 2nd 06, 03:44 AM posted to rec.radio.amateur.antenna
external usenet poster
 
First recorded activity by RadioBanter: Jul 2006
Posts: 137
Default guy wire for the ground wire

I'd avoid it. The conductivity of steel (stainless?) guy wire is much
lower than copper, maybe 40 times lower, so your 3/16th EHS is maybe
something like 20 gauge copper equivalent.

Dan

Ralph Mowery wrote:
I don't recall seeing it anywhere, but is there any problem with using some
left over guy wire (3/16 EHS) to go from the tower to a ground rod at the
base of a tower. Planning on going to about 60 feet with Rohn 25 and will
probably use a ground rod at the tower and maybe one at each of the guy
points. Just seems to me that if the correct clamps are used the wires and
tower would be the same material and not have a galvonic reaction.


  #3   Report Post  
Old November 2nd 06, 07:33 PM posted to rec.radio.amateur.antenna
external usenet poster
 
First recorded activity by RadioBanter: Jul 2006
Posts: 71
Default guy wire for the ground wire

On 1 Nov 2006 19:44:24 -0800, "
wrote:

I'd avoid it. The conductivity of steel (stainless?) guy wire is much
lower than copper, maybe 40 times lower, so your 3/16th EHS is maybe
something like 20 gauge copper equivalent.


3/16" is approximately 5 AWG. The ITT handbook gives the resistance
of copper-clad steel (a good enough approximation to zinc plated
steel) as about 1 ohm/1000'.

Compared to the resistance of a ground rod to Earth "connection" I
think that a few feet of steel wire resistance is in the noise.

I'd watch out for a zinc to copper connection tho.


Dan

Ralph Mowery wrote:
I don't recall seeing it anywhere, but is there any problem with using some
left over guy wire (3/16 EHS) to go from the tower to a ground rod at the
base of a tower. Planning on going to about 60 feet with Rohn 25 and will
probably use a ground rod at the tower and maybe one at each of the guy
points. Just seems to me that if the correct clamps are used the wires and
tower would be the same material and not have a galvonic reaction.


  #4   Report Post  
Old November 2nd 06, 08:30 PM posted to rec.radio.amateur.antenna
external usenet poster
 
First recorded activity by RadioBanter: Jul 2006
Posts: 168
Default guy wire for the ground wire

On Tue, 31 Oct 2006 23:45:05 GMT, "Ralph Mowery"
wrote:

I don't recall seeing it anywhere, but is there any problem with using some
left over guy wire (3/16 EHS) to go from the tower to a ground rod at the
base of a tower. Planning on going to about 60 feet with Rohn 25 and will
probably use a ground rod at the tower and maybe one at each of the guy
points. Just seems to me that if the correct clamps are used the wires and
tower would be the same material and not have a galvonic reaction.


Do you have codes or standards that provide guidance, or requirements?

The standard applicable here in Australia suggests that it is likely
that earthing conductors need to be 35mm^2 copper or better (~ 2AWG).

The conductor used for lightning protection should be sufficient to
carry the anticipated current without deterioration and without risk
of fire.

People often design for a scenario like 20kA for 0.1s.

I don't know how 3/16EHS performs in that scenario, but I venture that
it probably has csa of about 10mm^2, conductivity of a tenth of
copper, higher inductance than copper (which affects the voltage
rise), higher specific heat and higher melting point.

Perhaps it is safer to use copper of adequate size.

Owen
--
  #5   Report Post  
Old November 12th 06, 05:53 AM posted to rec.radio.amateur.antenna
external usenet poster
 
First recorded activity by RadioBanter: Jul 2006
Posts: 137
Default guy wire for the ground wire

Compared to the resistance of a ground rod to Earth "connection" I
think that a few feet of steel wire resistance is in the noise.


But the power-handling capability of that wire is much less than that
of the earth below the tower ;-) It would be a tad better at not
exploding than a 20AWG wire would, because it's more massive, mostly,
but I don't know that I'd want to use it as a primary grounding
conductor anyway.

Dan

Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Joining galvanised wire mesh (chicken wire) ground plane ferrymanr Antenna 6 October 9th 06 06:03 PM
Transformer Wire = Magnet Wire as a a Light-Weight Antenna Wire {Hidden] Stealth Antenna RHF Shortwave 1 June 1st 06 09:47 AM
Yacht Rf ground and radials Will Antenna 53 May 31st 06 04:22 AM
Question is 'it' a Longwire {Random Wire} Antenna -or- Inverted "L" Antenna ? RHF Shortwave 5 November 6th 05 04:52 AM
QST Article: An Easy to Build, Dual-Band Collinear Antenna Serge Stroobandt, ON4BAA Antenna 12 October 16th 03 07:44 PM


All times are GMT +1. The time now is 07:58 PM.

Powered by vBulletin® Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.
Copyright ©2004-2025 RadioBanter.
The comments are property of their posters.
 

About Us

"It's about Radio"

 

Copyright © 2017