Here is the results of my analysis of a 99 radial monople: Height 9 m, radial length from 0.5 to 10m, all conductors #14 AWG copper, ground Er = 16, resistivity 150 ohm - m. Radials 25 mm below ground. Antenna efficiency includes the surface wave. Radial Radial Radiation Ant Length Z Resistance Efficiency (m) (ohms) (ohms) (%) 0.5 63.0 - j 33.6 13.2 17.6 1.0 47.7 - j 18.2 13.2 21.7 1.5 41.8 - j 13.7 13.2 24.1 2.0 38.3 - j 12.5 13.2 25.7 2.5 35.7 - j 11.2 13.2 27.1 3.0 33.4 - j 10.8 13.2 28.3 3.5 31.6 - j 10.5 13.1 29.4 4.0 29.8 - j 10.1 13.1 30.6 4.5 28.2 - j 9.5 13.1 31.7 5.0 26.8 - j 8.9 13.1 32.8 5.5 25.7 - j 8.2 13.1 33.8 6.0 24.7 - j 8.0 13.2 34.7 6.5 23.9 - j 6.9 13.2 35.6 7.0 23.2 - j 6.2 13.3 36.4 7.5 22.6 - j 5.5 13.4 37.7 8.0 22.1 - j 4.8 13.5 38.0 8.5 21.6 - j 4.2 13.7 38.8 9.0 21.2 - j 3.5 13.8 39.5 9.5 20.9 - j 2.9 14.0 40.2 10.0 20.7 - j 2.2 14.2 40.9 Note that the radiation resistance is computed from the total radiated power (including surface wave) divided by the RMS base current squared. The radial input impedance is derived from the difference between the antenna input impedance and the radiation resistance. A fraction of an ohm can be attributed to the copper losses in the monopole. Also some of the imaginary part of the radial impedance must be due, in part, to the input impedance of the vertical section. With 0.5 m radials the surface wave accounts for 2% of the total radiated power. With 10 m radials the surface wave accounts for 5% of the TRP. Frank CM Reg's 99 radial Vertical CM (WG) CE GW 2 1 0 0 0 0 0.0968 -0.025 0.00082 GW 35 4 0 0.0968 -0.025 0.026 0.5 -0.025 0.00082 GW 70 4 0 0.0968 -0.025 0 0.5 -0.025 0.00082 GW 105 4 0 0.0968 -0.025 -0.026 0.5 -0.025 0.00082 GR 1 33 GE -1 2 GN 2 0 0 0 16 0.0067 FR 0 1 0 0 8.07 0.01 LD 5 0 0 0 5.8001E7 WG EN CM Reg's 99 radial CM (GF) CE GF GW 1 90 0 0 9 0 0 0 0.00082 GE -1 EX 0 1 90 00 83.83328192 0 LD 5 0 0 0 5.8001E7 RP 1 101 1 0000 200 0 -2 1 200 RP 0 91 1 1000 0 0 1 1 RP 0 19 73 1002 -90 0 5.00000 5.00000 NE 1 1 46 1 200 45 90 1.0 1.0 1 NH 1 1 1 1 200 89 90 1.0 1.0 1 EN |
#2
![]() |
|||
|
|||
![]()
I'm curious: How did you calculate the total radiated power including
surface wave, and how did you determine what fraction of the radiated power is in the surface wave? Roy Lewallen, W7EL Frank's wrote: . . . Note that the radiation resistance is computed from the total radiated power (including surface wave) divided by the RMS base current squared. . . . |
#3
![]() |
|||
|
|||
![]()
Frank,
You don't mention frequency. I assume it is still 8.07 MHz. There's something seriously wrong! The only change you have made (or I think you have changed) is to increase the number of radials from 36 to 99. Yet, for a length of 10 metres, the resistance of the radials ground connection has INCREASED from a few ohms (for 36 radials) to 20.7 ohms (for 99 radials). This is impossible! It should either decrease to an even lower value or at least remain the same. Although I am not particularly interested in radiation resistance, there is also something seriously wrong with Rrad. Rrad for a 1/4-wave vertical ought to be in the region of 34 ohms - not as low as 13 ohms. I think you use Rrad to calculate radials input resistance in which I AM very interested. I think you subtract the antenna input impedance, from the total impedance of antenna + radials, to obtain the radials input resistance. Rrad + conductor resistance is the feedpoint resistance of the antenna. You make it about 34 - 13 = 21 ohms too low. If you subtract 21 ohms from YOUR radials input resistance values, then the EXPECTED very low input resistance values for 99 radials are obtained. But, of course, the radials input resistance should never become negative. If you are unable to find where the error arises then use my value of Antenna Feedpoint Resistance = 33.8 ohms (which I have just calculated.) Could you please investigate your results and apply corrections? If you are unable to determine the resonant input resistance of the 9-metre vertical antenna ( jX = 0) then use my value of 33.8 ohms which, as likely as not, will not be exactly correct. .................................................. ..................... ................................. Then change antenna height to exactly 3 metres and change frequency to about 25 MHz. The exact frequency being that at which the antenna is 1/4-wave resonant with the feedpoint reactance being zero. Repeat measurements for 99 radials. Such measurements will be far more accurate than if they were made in the field. I have some nice graphs of input impedance, R + jX, versus radial length for work you have already done. They tell me quite a lot. ---- Reg. ======================================= Reg: Here is the results of my analysis of a 99 radial monople: Height 9 m, radial length from 0.5 to 10m, all conductors #14 AWG copper, ground Er = 16, resistivity 150 ohm - m. Radials 25 mm below ground. Antenna efficiency includes the surface wave. Radial Radial Radiation Ant Length Z Resistance Efficiency (m) (ohms) (ohms) (%) 0.5 63.0 - j 33.6 13.2 17.6 1.0 47.7 - j 18.2 13.2 21.7 1.5 41.8 - j 13.7 13.2 24.1 2.0 38.3 - j 12.5 13.2 25.7 2.5 35.7 - j 11.2 13.2 27.1 3.0 33.4 - j 10.8 13.2 28.3 3.5 31.6 - j 10.5 13.1 29.4 4.0 29.8 - j 10.1 13.1 30.6 4.5 28.2 - j 9.5 13.1 31.7 5.0 26.8 - j 8.9 13.1 32.8 5.5 25.7 - j 8.2 13.1 33.8 6.0 24.7 - j 8.0 13.2 34.7 6.5 23.9 - j 6.9 13.2 35.6 7.0 23.2 - j 6.2 13.3 36.4 7.5 22.6 - j 5.5 13.4 37.7 8.0 22.1 - j 4.8 13.5 38.0 8.5 21.6 - j 4.2 13.7 38.8 9.0 21.2 - j 3.5 13.8 39.5 9.5 20.9 - j 2.9 14.0 40.2 10.0 20.7 - j 2.2 14.2 40.9 Note that the radiation resistance is computed from the total radiated power (including surface wave) divided by the RMS base current squared. The radial input impedance is derived from the difference between the antenna input impedance and the radiation resistance. A fraction of an ohm can be attributed to the copper losses in the monopole. Also some of the imaginary part of the radial impedance must be due, in part, to the input impedance of the vertical section. With 0.5 m radials the surface wave accounts for 2% of the total radiated power. With 10 m radials the surface wave accounts for 5% of the TRP. Frank CM Reg's 99 radial Vertical CM (WG) CE GW 2 1 0 0 0 0 0.0968 -0.025 0.00082 GW 35 4 0 0.0968 -0.025 0.026 0.5 -0.025 0.00082 GW 70 4 0 0.0968 -0.025 0 0.5 -0.025 0.00082 GW 105 4 0 0.0968 -0.025 -0.026 0.5 -0.025 0.00082 GR 1 33 GE -1 2 GN 2 0 0 0 16 0.0067 FR 0 1 0 0 8.07 0.01 LD 5 0 0 0 5.8001E7 WG EN CM Reg's 99 radial CM (GF) CE GF GW 1 90 0 0 9 0 0 0 0.00082 GE -1 EX 0 1 90 00 83.83328192 0 LD 5 0 0 0 5.8001E7 RP 1 101 1 0000 200 0 -2 1 200 RP 0 91 1 1000 0 0 1 1 RP 0 19 73 1002 -90 0 5.00000 5.00000 NE 1 1 46 1 200 45 90 1.0 1.0 1 NH 1 1 1 1 200 89 90 1.0 1.0 1 EN |
#4
![]() |
|||
|
|||
![]()
Roy, I use a couple of methods. First, the RP card as follows:
RP 0 19 73 1002 -90 0 5.0 5.0 Where, the last digit of "XNDA" is "2", and the average gain is calculated providing the following output: AVERAGE POWER GAIN= 3.00224E-01 SOLID ANGLE USED IN AVERAGING=( 2.0000)*PI STERADIANS. POWER RADIATED ASSUMING RADIATION INTO 4*PI STERADIANS = 1.15944E+01 WATTS The input power for this particular test was 38.619 W. As a verification I numerically integrate (Excel) the total radiated E-field over a hemispherical region. The elemental area I use is r^2*sine(theta)*d(theta)*d(phi). Of course the E field is normalized to 1 m, and "r" is obviously "1". d(phi), and d(theta) are both one degree. The results are in very close agreement with the radiation, as above, in 4*PI Steradians/2. I therefore have a fairly accurate figure for the total radiated power without the surface wave. For the next step I use the following RP card: RP 1 101 1 0000 200 0 -2 1 200. The problem is, of course, that the results are only available in cylindrical coordinates. Where the total ground wave, and sky wave, is computed in the far field (Where I have taken the far field to be 200 meters at 8 MHz) from Z = 200 to Z = 0, in steps of 2 meters (From theta(zenith) 45 to 90). I then normalize these data to a radial distance of 1 m; taking only those data points close to (theta) integral degrees. Picking out these data points, taken from the NEC output file, in Excel is a fairly tedious process. I then "cut and paste" these normalized data into my "integrating" Excel spread sheet; replacing the previously computed "sky wave" data from 45 to 90 degrees. These results then give me the total radiated power, including the surface wave. I can then easily compute the contribution, to the total radiated power, by the surface wave. When I replace the data, in the integrating spread sheet, the data at 44 degrees is very close to the 45 degree field strength, obtained from the cylindrical coordinates. Hope you managed to follow my rambling description. To say the least it requires a lot of tedious data manipulation with Excel. If you are interested I can e-mail my spread sheets, NEC input and output files, etc. Regards, Frank (VE6CB) "Roy Lewallen" wrote in message ... I'm curious: How did you calculate the total radiated power including surface wave, and how did you determine what fraction of the radiated power is in the surface wave? Roy Lewallen, W7EL Frank's wrote: . . . Note that the radiation resistance is computed from the total radiated power (including surface wave) divided by the RMS base current squared. . . . |
#5
![]() |
|||
|
|||
![]()
On Sat, 19 Aug 2006 00:52:40 GMT, "Frank's"
wrote: .... Hope you managed to follow my rambling description. To say the least it requires a lot of tedious data manipulation with Excel. If you are interested I can e-mail my spread sheets, NEC input and output files, etc. Frank, You might want to consider a scripting environment to build, run, and summarise NEC runs. Windows lacks a good scripting language for this type of application. Fortunately there are others available, and at no charge. Two that I have used are PERL and Python. I prefer PERL mainly for historical reasons and the huge base of packages to extend the PERL base, though Python is probably a better designed language, and less likely to change radically (as PERL looks likely to do with V6). Importantly, both natively support complex number type. For instance, you can write in PERL: #calculate Zo and gamma my $a=$R+i*2*PI*$this-{f}*$L; my $b=$G+i*2*PI*$this-{f}*$C; $this-{zo}=($a/$b)**0.5; $this-{gamma}=($a*$b)**0.5; PERL is excellent for reading megabytes of NEC output and extracting key figures for summarisation. An example, I recently wanted to explore the relationship between predicted beamwidth (in E and H planes separately) and gain for DL6WU long boom Yagis. I built and ran literally hundreds of models with pattern reporting at 0.1deg intervals, producing over 50MB of output. Models were automatically generated from a PERL port of the DL6WU design algorithms, and NEC runs of the generated models were automated. Half power point was found by linear interpolation between 0.1deg points around the half power points. If I did that by hand, I would be working for months, whereas a half hour of scripting produced a solution that was more accurate and reusable. Is there a place for Excel? Certainly, I usually create tab delimited summary files with PERL scripts and drop them on Excel to the final ad-hoc analysis and presentation. DPLOT is also a pretty neat tool for graphical analysis and presentation. For example, the regression analysis of the data from the study above http://www.vk1od.net/dl6wu/new_pa2.gif was calculated and displayed using DPLOT. Worth the investment in learning PERL (or the like)! http://www.perl.org/ (You need the Activestate PERL for Windows.) http://www.python.org/ http://www.dlot.com/ Owen -- |
#6
![]() |
|||
|
|||
![]()
On Sat, 19 Aug 2006 22:44:04 GMT, Owen Duffy wrote:
On Sat, 19 Aug 2006 00:52:40 GMT, "Frank's" wrote: ... Hope you managed to follow my rambling description. To say the least it requires a lot of tedious data manipulation with Excel. If you are interested I can e-mail my spread sheets, NEC input and output files, etc. You might want to consider a scripting environment to build, run, and summarise NEC runs. Windows lacks a good scripting language for this type of application. Fortunately there are others available, and at no charge. Two that I have used are PERL and Python. And, there's REXX (several -- recommend Regina for one) which has _great_ string handling capabilities. Jonesy -- Marvin L Jones | jonz | W3DHJ | linux 38.24N 104.55W | @ config.com | Jonesy | OS/2 *** Killfiling google posts: http//jonz.net/ng.htm |
#7
![]() |
|||
|
|||
![]()
On 20 Aug 2006 00:52:41 GMT, Allodoxaphobia
wrote: And, there's REXX (several -- recommend Regina for one) which has _great_ string handling capabilities. I haven't followed the fortunes of REXX since I taught some "Safe REXX" courses in the ealy '90s. I do recall that in the 80s, IBM wanted to hand it over to the ANSI to be made a standard. That should have nobbled its progress sufficiently to be overtaken by developments originating from the Unix world. But yes, I see that enthusiasts have kept it alive. Does it have (PC)REs, might be an option for people who don't want to embrace REs. Owen -- |
#8
![]() |
|||
|
|||
![]()
Reg,
The frequency is still 8.07 MHz. I was also puzzled by the radiation resistance, but I arrived at the value differently than in previous models. Anyway, I think I have discovered the error. In computing the surface wave at 200 m I assumed the loss would be insignificant. This does not appear to be true. For example; at a 26 degree elevation angle normalization of the E-field to one meter produces essentially the same result from either: 200 meters, or 400 meters. At zero degree elevation angle, where the surface wave dominates; normalization from 200 m or 400 m produces significantly different results -- as shown below: Elevation Distance E- field Angle (m) normalized (deg.) to 1 meter (V) 26 200 83.0 26 400 83.3 0 200 67.5 0 400 45.5 I had this at the back of my mind when making the calculations. To be honest it is pretty much a no brainer, since it is well known that the surface wave diminishes rapidly at the higher frequencies. All your comments are noted. For the moment I would like to perform an integration of the Poynting Vector in the near field. Hopefully it will provide a more realistic radiation resistance. Now to figure out how to do this in Excel. Frank "Reg Edwards" wrote in message ... Frank, You don't mention frequency. I assume it is still 8.07 MHz. There's something seriously wrong! The only change you have made (or I think you have changed) is to increase the number of radials from 36 to 99. Yet, for a length of 10 metres, the resistance of the radials ground connection has INCREASED from a few ohms (for 36 radials) to 20.7 ohms (for 99 radials). This is impossible! It should either decrease to an even lower value or at least remain the same. Although I am not particularly interested in radiation resistance, there is also something seriously wrong with Rrad. Rrad for a 1/4-wave vertical ought to be in the region of 34 ohms - not as low as 13 ohms. I think you use Rrad to calculate radials input resistance in which I AM very interested. I think you subtract the antenna input impedance, from the total impedance of antenna + radials, to obtain the radials input resistance. Rrad + conductor resistance is the feedpoint resistance of the antenna. You make it about 34 - 13 = 21 ohms too low. If you subtract 21 ohms from YOUR radials input resistance values, then the EXPECTED very low input resistance values for 99 radials are obtained. But, of course, the radials input resistance should never become negative. If you are unable to find where the error arises then use my value of Antenna Feedpoint Resistance = 33.8 ohms (which I have just calculated.) Could you please investigate your results and apply corrections? If you are unable to determine the resonant input resistance of the 9-metre vertical antenna ( jX = 0) then use my value of 33.8 ohms which, as likely as not, will not be exactly correct. .................................................. .................... ................................ Then change antenna height to exactly 3 metres and change frequency to about 25 MHz. The exact frequency being that at which the antenna is 1/4-wave resonant with the feedpoint reactance being zero. Repeat measurements for 99 radials. Such measurements will be far more accurate than if they were made in the field. I have some nice graphs of input impedance, R + jX, versus radial length for work you have already done. They tell me quite a lot. ---- Reg. ======================================= Reg: Here is the results of my analysis of a 99 radial monople: Height 9 m, radial length from 0.5 to 10m, all conductors #14 AWG copper, ground Er = 16, resistivity 150 ohm - m. Radials 25 mm below ground. Antenna efficiency includes the surface wave. Radial Radial Radiation Ant Length Z Resistance Efficiency (m) (ohms) (ohms) (%) 0.5 63.0 - j 33.6 13.2 17.6 1.0 47.7 - j 18.2 13.2 21.7 1.5 41.8 - j 13.7 13.2 24.1 2.0 38.3 - j 12.5 13.2 25.7 2.5 35.7 - j 11.2 13.2 27.1 3.0 33.4 - j 10.8 13.2 28.3 3.5 31.6 - j 10.5 13.1 29.4 4.0 29.8 - j 10.1 13.1 30.6 4.5 28.2 - j 9.5 13.1 31.7 5.0 26.8 - j 8.9 13.1 32.8 5.5 25.7 - j 8.2 13.1 33.8 6.0 24.7 - j 8.0 13.2 34.7 6.5 23.9 - j 6.9 13.2 35.6 7.0 23.2 - j 6.2 13.3 36.4 7.5 22.6 - j 5.5 13.4 37.7 8.0 22.1 - j 4.8 13.5 38.0 8.5 21.6 - j 4.2 13.7 38.8 9.0 21.2 - j 3.5 13.8 39.5 9.5 20.9 - j 2.9 14.0 40.2 10.0 20.7 - j 2.2 14.2 40.9 Note that the radiation resistance is computed from the total radiated power (including surface wave) divided by the RMS base current squared. The radial input impedance is derived from the difference between the antenna input impedance and the radiation resistance. A fraction of an ohm can be attributed to the copper losses in the monopole. Also some of the imaginary part of the radial impedance must be due, in part, to the input impedance of the vertical section. With 0.5 m radials the surface wave accounts for 2% of the total radiated power. With 10 m radials the surface wave accounts for 5% of the TRP. Frank CM Reg's 99 radial Vertical CM (WG) CE GW 2 1 0 0 0 0 0.0968 -0.025 0.00082 GW 35 4 0 0.0968 -0.025 0.026 0.5 -0.025 0.00082 GW 70 4 0 0.0968 -0.025 0 0.5 -0.025 0.00082 GW 105 4 0 0.0968 -0.025 -0.026 0.5 -0.025 0.00082 GR 1 33 GE -1 2 GN 2 0 0 0 16 0.0067 FR 0 1 0 0 8.07 0.01 LD 5 0 0 0 5.8001E7 WG EN CM Reg's 99 radial CM (GF) CE GF GW 1 90 0 0 9 0 0 0 0.00082 GE -1 EX 0 1 90 00 83.83328192 0 LD 5 0 0 0 5.8001E7 RP 1 101 1 0000 200 0 -2 1 200 RP 0 91 1 1000 0 0 1 1 RP 0 19 73 1002 -90 0 5.00000 5.00000 NE 1 1 46 1 200 45 90 1.0 1.0 1 NH 1 1 1 1 200 89 90 1.0 1.0 1 EN |
#9
![]() |
|||
|
|||
![]()
You might want to consider a scripting environment to build, run, and
summarise NEC runs. Windows lacks a good scripting language for this type of application. Fortunately there are others available, and at no charge. Two that I have used are PERL and Python. I prefer PERL mainly for historical reasons and the huge base of packages to extend the PERL base, though Python is probably a better designed language, and less likely to change radically (as PERL looks likely to do with V6). Importantly, both natively support complex number type. For instance, you can write in PERL: #calculate Zo and gamma my $a=$R+i*2*PI*$this-{f}*$L; my $b=$G+i*2*PI*$this-{f}*$C; $this-{zo}=($a/$b)**0.5; $this-{gamma}=($a*$b)**0.5; PERL is excellent for reading megabytes of NEC output and extracting key figures for summarisation. An example, I recently wanted to explore the relationship between predicted beamwidth (in E and H planes separately) and gain for DL6WU long boom Yagis. I built and ran literally hundreds of models with pattern reporting at 0.1deg intervals, producing over 50MB of output. Models were automatically generated from a PERL port of the DL6WU design algorithms, and NEC runs of the generated models were automated. Half power point was found by linear interpolation between 0.1deg points around the half power points. If I did that by hand, I would be working for months, whereas a half hour of scripting produced a solution that was more accurate and reusable. Is there a place for Excel? Certainly, I usually create tab delimited summary files with PERL scripts and drop them on Excel to the final ad-hoc analysis and presentation. DPLOT is also a pretty neat tool for graphical analysis and presentation. For example, the regression analysis of the data from the study above http://www.vk1od.net/dl6wu/new_pa2.gif was calculated and displayed using DPLOT. Worth the investment in learning PERL (or the like)! http://www.perl.org/ (You need the Activestate PERL for Windows.) http://www.python.org/ http://www.dlot.com/ Owen Thanks for the info Owen, also the comments from Jonsey. The scripting languages look very interesting. From your sample code above it does look very logical and easy to use; not to mention that it can handle complex numbers. Regards, Frank |
#10
![]() |
|||
|
|||
![]()
Worth the investment in learning PERL (or the like)!
http://www.perl.org/ (You need the Activestate PERL for Windows.) http://www.python.org/ http://www.dlot.com/ Owen Thanks for the info Owen, also the comments from Jonsey. The scripting languages look very interesting. From your sample code above it does look very logical and easy to use; not to mention that it can handle complex numbers. Still thinking about the scripting languages, but wanted to finish the analysis with Excel. While trying to set up the "Cross product matrix" I ran into a major formatting problem with Excel. When I convert the polar form of a complex number (two cells) to rectangular form (single cell); the cell size expands to 42 digits in scientific format. The problem lies in the fact that Excel treats complex numbers as text, and they cannot be formatted in the normal way. I have searched several bookstores, and looked at every major book on Excel, and VBA macros. Complex numbers are treated in only a superficial way, or not at all. Microsoft does discuss the problem concerning XL2000 at: http://support.microsoft.com/?kbid=213294 The VB code does not make a lot of sense to me, also in particular the statement: "=FormatComplex(A1,"0.00","0.0000")" does not appear to work, nor does their "Sample VBA Procedure". This may be due to the fact that I am using Excel 97. Anyway, this is not really the forum for this discussion, but others attempting to deal with the NEC output file analysis, may have some ideas. It looks like it may be some time before I can arrive at any results -- probably with some scripting code. Frank |