Home |
Search |
Today's Posts |
#31
![]() |
|||
|
|||
![]()
On Sat, 14 Apr 2007 16:04:55 -0700, Roy Lewallen wrote:
Walt, before digging into your recent posting, I'd really like to get one issue settled. I think it would be helpful in our discussion. The issue is: Can you find even one example of any transmission line problem which cannot be solved, or a complete analysis done, without making the assumption that waves reflect from a "virtual short" or "virtual open"? That is, any example where such an assumption is necessary in order to find the currents, voltages, and impedances, and the magnitude and phase of forward and reverse voltage and current waves? Roy Lewallen, W7EL No Roy, of course not. I am not attempting to assert that reflection coefficients should be used in such an analysis. I'm only asserting that it's another way of performing an analysis, one that I believe paints a more visible picture of the how the pertinent waves behave in the circuit. If I still haven't persuaded you that it's a viable way of analyzing the impedance matching function then I'll back off and not pursue the issue any further. Incidentally, you didn't answer my questions. Walt |
#32
![]() |
|||
|
|||
![]()
Walter Maxwell wrote in
: .... Re your worked solution (above), I agree that the normalised admittance looking into 30deg of line with load 16.667+j0 is about 1-j1.1547 (not the different sign). Yes Owen, you're right. I added the y values at the last moment, and didn't catch the errors. Both the line and stub signs are reversed. Sorry 'bout that. Ok. I make the normalised admittance looking into the stub about 0+j1.15 (and the reflection coefficient about 0.5-98, how do you get 1+j1.15? Normalized y looking into the stub directly is y = 0 + 1.1547, but looking at the stub while on the line at the 30° point is y = 1 + 1.1547. To view the stub separately on the line the line is terminated in 50 ohms, because the real component of the line impedance at the match point is 50 ohms. You have a junction where three current paths appear in parallel, we can add the admittances of each of those paths. We are agreed that admittance of the load+30deg line is 1-j1.15, and that of the stub is 0+j1.15, so the only place the additional 1+j0 can come from is the source+line branch. If that is the case, then your explanation of the stub (which I assume to be a steady state explanation because you are talking about frequency domain admittances), depends on the source admittance (or impedance). If the equivalent source impedance at the junction figures in the calcs, you are saying that the VSWR on the line from source to junction depends on the source impedance... I thought we got over that error. My view is that the stub in shunt with the 30deg line+load results in an equivalent impedance of approximately 50+j0 at the junction, irrespective of what is on the source side of the junction. Owen |
#33
![]() |
|||
|
|||
![]()
Walter Maxwell wrote:
On Sat, 14 Apr 2007 16:04:55 -0700, Roy Lewallen wrote: Walt, before digging into your recent posting, I'd really like to get one issue settled. I think it would be helpful in our discussion. The issue is: Can you find even one example of any transmission line problem which cannot be solved, or a complete analysis done, without making the assumption that waves reflect from a "virtual short" or "virtual open"? That is, any example where such an assumption is necessary in order to find the currents, voltages, and impedances, and the magnitude and phase of forward and reverse voltage and current waves? Roy Lewallen, W7EL No Roy, of course not. I am not attempting to assert that reflection coefficients should be used in such an analysis. I'm only asserting that it's another way of performing an analysis, one that I believe paints a more visible picture of the how the pertinent waves behave in the circuit. We're certainly not communicating well! I have never questioned that the use of "virtual shorts" is another way of performing an analysis, nor that it helps visualize some of the things going on. If I still haven't persuaded you that it's a viable way of analyzing the impedance matching function then I'll back off and not pursue the issue any further. Nor have I questioned that it's a viable way of analyzing the impedance matching function. If you'll read what I've written, you'll hopefully see that my only point of contention is with your claim that waves reflect from a "virtual short". They do not. And the lack of a single example of a system whose analysis requires this to happen is evidence that they do not. If you back off and not pursue the issue any further, you'll continue with your belief that "virtual shorts" cause reflections. And I'm afraid that will detract from the wealth of accurate and useful things you do say. So please continue. But don't waste time arguing that the concept of "virtual shorts" is a useful analytical tool. I've always agreed with that, and haven't seen any postings indicating anyone else doesn't. Incidentally, you didn't answer my questions. I wanted to get an answer to mine, first. Now that I have, I'll answer yours. Roy Lewallen, W7EL |
#34
![]() |
|||
|
|||
![]()
Walter Maxwell wrote:
Consider my two explanations, or definitions of what I consider a virtual short--perhaps it should have a different name, because of course 'virtual' implies non-existence. The short circuit evident at the input of the two line examples I presented---do you agree that short circuits appear at the input of the two lines? If so, what would you call them? I'd call them "virtual shorts". If they were short circuits, we should be able to connect a wire across the transmission line at that point with no change in transmission line operation. But we can't. While things will look the same on the generator side, they won't be the same beyond the real short. So they aren't short circuits. Roy, I'd like for you to take another, but perhaps closer look at the summarizing of the reflection coefficients below. I originally typed in the wrong value for the magnitude of the resultant coefficients. With the corrected magnitudes in place, the two paragraphs following the summarization now make more sense, because the short circuit established at the stub point leads correctly to the wave action that occurs there. Summarizing reflection coefficient values at stub point with stub in place: Line coefficients: voltage 0.5 at +120°, current -60° (y = 1 + j1.1547) Stub coefficients: voltage 0.5 at -120°, current +60° (y = 1 - j1.1547) Resultant coefficients: voltage 0.5 at 180°, current 0.5 at 0° WRONG Resultant coefficients: voltage 1.0 at 180°, current 1.0 at 0° CORRECT Repeating from my original post for emphasis: These two resultant reflection coefficients resulting from the interference between the load-reflected wave at the stub point and the reflected wave produced by the stub define a virtual short circuit established at the stub point. There's no need to repeat this. I'm well acquainted with transmission line phenomena, and understand fully what's happening. I have no disagreement with this analysis. I would draw attention to the fact that the "virtual short" is, as you say, simply the superposition (interference) of traveling waves. So there is nothing at that point except the traveling waves which pass through that point. The following paragraph shows how the phases of the reflected waves become in phase with the source waves so that the reflected waves add directly to the source waves, establishing the forward power, which we know exceed the source power when the reflected power is re-reflected. The same concept applies to antena tuners. Sorry, I'm not going to divert onto the topic of propagating power, either instantaneous or average. If that concept is required in order to show that waves interact with each other, then it simply shows that the concept is invalid. Let's stick to voltages and currents. If that's not adequate, then I'll exit at this point, and turn the discussion over to Cecil. That's his domain, not mine. Again repeating for emphasis: Let's now consider what occurs when a wave encounters a short circuit. Ok. We know that the voltage wave encounters a phase change of 180°, while the current wave encounters zero change in phase. Note that the resultant voltage is at 180°, so the voltage phase changes to 0° on reflection at the short circuit, and is now in phase with the source voltage wave. In addition, the resultant current is already at 0°, and because the current phase does not change on reflection at the short circuit, it remains at 0° and in phase with source current wave. Consequently, the reflected waves add in phase with the source waves, Ok so far. . . thus increasing the forward power in the line section between the stub and the load. Again, let's leave power out of it, ok? Keep in mind that the short at the stub point is a one-way short, diode like, as you say, because in the forward direction the voltage reflection coefficient rho is 0.0 at 0°, while in the reverse direction, rho at the stub point is 1.0 at 180°, which is why it's a one-way short. The voltages, currents, waves, and impedances impedances on the line are just the same as if there were a diode-short at that point. Which is why it's a useful analytical tool. But all there really is at that point are some interfering waves, traveling through that point unhindered. You say that no total re-reflection occurs at the stub point. However, with a perfect match the power rearward of the stub is zero, and all the source power goes to the load in the forward direction. Is that not total reflection? Not from the "virtual short" -- it only looks like it. The re-reflection is actually occurring from the end of the stub and from the load, not from the "virtual short". If, for example, you suddenly increased the source voltage, there would be no reflection as that change propagated through that "virtual short". (That is, after a delay equal to the round-trip time to the "virtual short", you'd see no change.) The apparent reflection from that point wouldn't appear until the change propagated to the end of the stub and to the load (going right through the "virtual short" unhindered), reflected from them, and arrived back at the "virtual short" point. This is one of the ways you can tell that a "virtual short" isn't a real short. Under steady state conditions, it looks just like a real one. But it isn't. Waves which seem to be reflecting from it are really reflecting from the end of the stub and from the load -- they're passing right through the "virtual short", in both directions. Using the numbers of my bench experiment, assuming a source power of 1 watt, and with the magnitude rho of 0.04, power going rearward of the stub is 0.0016 w, while the power absorbed by the load is 0.9984 w, the sum of which is 1 w. The SWR seen by the source is 1.083:1, and the return loss in this experiment is 27.96 dB, while the power lost to the load is 0.0070 dB. From a ham's practical viewpoint the reflected power is totally re-reflected. Sorry, you're going to have to do this without propagating waves of average power, or I'm outta here. In my example using the 49° stub the capacitive reactance it established at its input is Xc = -57.52 ohms. Thus its inductive susceptance B = 0.0174 mhos, which cancels the capacitive line susceptance B = -0.0174 mhos appearing at the stub point. My point is that the 49° stub can be replaced with a lumped capacitance Xc = -57.52 ohms directly on the line with the same results as with the stub--with the same reflection coefficients. That's fine, I agree. In this case one cannot say that the re-reflection results from the physical open circuit terminating the stub line. I most certainly can! And do. I don't see how your example furnishes any proof or even evidence of wave interaction. I can come to the same conclusion without any assumption of wave interaction, and you have agreed (in your response to my question about finding an example that requires interaction for analysis) that this can always be done. Various posters have termed my approach as a 'short cut'. I disagree. I prefer to consider it as the wave analysis to the stub-matching procedure, in contrast to the traditional method of simply saying that the stub reactance cancels the line reactance at the point on the line where the line resistance R = Zo. In my mind the wave analysis presents a more detailed view of what's actually happening to the pertinent waves while the impedance match is being established. I'm sorry, I disagree. It's a less detailed view, and it conceals what's really going on. Roy Lewallen, W7EL |
#35
![]() |
|||
|
|||
![]()
K7ITM wrote:
. . . It's a useful visualization tool and design aid; it's a poor analysis tool at best. At worst, it will lull you into building something that just won't work, wasting time and resources. In my opinion, the potential harm can be much worse. If it causes you to buy into the notion that traveling waves interact in a linear medium, that opens the door to a whole universe of invalid conclusions. We've seen some of those promoted very vigorously in this newsgroup. Roy Lewallen, W7EL |
#36
![]() |
|||
|
|||
![]() |
#37
![]() |
|||
|
|||
![]()
Roy Lewallen wrote:
I don't see how your example furnishes any proof or even evidence of wave interaction. Are you saying that wave interaction doesn't exist? -- 73, Cecil http://www.w5dxp.com |
#38
![]() |
|||
|
|||
![]()
Roy Lewallen wrote:
K7ITM wrote: . . . It's a useful visualization tool and design aid; it's a poor analysis tool at best. At worst, it will lull you into building something that just won't work, wasting time and resources. In my opinion, the potential harm can be much worse. If it causes you to buy into the notion that traveling waves interact in a linear medium, that opens the door to a whole universe of invalid conclusions. Here is how Hecht described interference in "Optics": "... interference corresponds to the *interaction* of two or more lightwaves yielding a resultant irradiance that deviates from the sum of the component irradiances." If traveling waves cannot interact in a linear medium, why does Hecht say they do indeed interact? To deny the body of laws of physics regarding EM waves from the field of optics is an example of extreme ignorance. -- 73, Cecil http://www.w5dxp.com |
#39
![]() |
|||
|
|||
![]()
Roy Lewallen wrote:
If it causes you to buy into the notion that traveling waves interact in a linear medium, that opens the door to a whole universe of invalid conclusions. Roy, seems you are the one with the invalid conclusions. Here is a java-script of "traveling wave interaction in a linear medium". http://micro.magnet.fsu.edu/primer/j...ons/index.html "... when two waves of equal amplitude and wavelength that are 180-degrees ... out of phase with each other meet, they are not actually annihilated, ... All of the photon energy present in these waves must somehow be recovered or redistributed in a new direction, according to the law of energy conservation ... Instead, upon meeting, the photons are redistributed to regions that permit constructive interference, so the effect should be considered as a redistribution of light waves and photon energy rather than the spontaneous construction or destruction of light." Does energy being redistributed in new directions really look like a lack of interaction to you? -- 73, Cecil http://www.w5dxp.com |
#40
![]() |
|||
|
|||
![]()
On Apr 14, 6:06 pm, Roy Lewallen wrote:
K7ITM wrote: . . . It's a useful visualization tool and design aid; it's a poor analysis tool at best. At worst, it will lull you into building something that just won't work, wasting time and resources. In my opinion, the potential harm can be much worse. If it causes you to buy into the notion that traveling waves interact in a linear medium, that opens the door to a whole universe of invalid conclusions. We've seen some of those promoted very vigorously in this newsgroup. Roy Lewallen, W7EL Yes, you're right, Roy. I guess I didn't consider that because I'm not very likely to buy into it, but from the point of view of someone just learning about linear systems, it's a danger. The analogy may not be prefect, but I think it's a lot like the usefulness of the idea of a "virtual ground" at the inverting input of an op amp. But it's a virtual ground only under specific conditions: strong negative feedback is active, and the non-inverting input is at (AC, at least) ground potential. For it to be a useful concept without too many pitfalls, the person using it has to be aware that the conditions that make it a good approximation don't always hold. Similarly for a "virtual short" on a line. Again, though, it IS useful to me to think along these lines, when looking to do something useful with stubs: I want to kill frequency W, so I can put a stub across my line that's half a wave long at W, shorted at the far end. At the same time I want to pass V, and the stub I just put there to kill W has reactance X at frequency V. If I put another stub with reactance -X at freq V across the line there, it will let V through with minimum effect. Now go calculate how well it will perform with particular lines. So, to come up with a design to try, I do think about how stubs behave, in a general sense, including things like "a half-wave line shorted at the far end echos a short", but with the programs I have readily available, it's silly to rely on approximations that drop the line attenuation, when I want to know how my idea will actually work when I build it. Cheers, Tom |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
Stub Matching software ? | Antenna | |||
Analyzing Woger | General | |||
Analyzing Woger | Policy | |||
A Subtle Detail of Reflection Coefficients (but important to know) | Antenna | |||
A Subtle Detail of Reflection Coefficients (but important to | Antenna |