I'm getting ready to install my tree mounted 80 m vertical now that the
ground is thawing. It will be a 1/4 wave vertical for 80 meters. I have a question regarding the radials I'll be putting out. I was planning on using solid #12 copper, and was going to lay out about 500 feet total of radial. Am I better off to use fewer and longer, or shorter and more? I'm inclined toward 10 50 foot radials. I have heard opposing views on the "proper" length of radials. (I'm assuming that longer and more would be much better, but I have some practical considerations here) - Mike KB3EIA - |
#2
![]() |
|||
|
|||
![]()
Mike,
I assume you will have ground surface or shallow buried radials. There are hardly any resonant effects in shallow-buried radials so no need to concern yourself with particular lenghts. You will be far better off with more and shorter wires. The attenuation along radial wires is quite high. There's no current flowing in them beyond a small fraction of a wavelength from the focal point. They may as well not be there. Wire diameter selected solely on your ideas about durability. Enamelled copper wire is fine and may be less expensive, easier to obtain than the bare stuff. Not much point in having radials longer than 1/10th or 1/15th wavelengths in moderately good soil at the lowest frequency of interest. A little longer in poor soil. Shorter in very good soil. Moisture content and fertility is the guide. Begin with one radial and increase the number by 50% until the RECEIVED signal strength from lower frequency, stable, reliable transmitters stops increasing. Then add a few more for luck. You will probably end up with fewer radials than recommended in the handbooks. ---- Reg, G4FGQ |
#3
![]() |
|||
|
|||
![]()
Reg Edwards wrote:
Mike, I assume you will have ground surface or shallow buried radials. They will be shallow buried. There are hardly any resonant effects in shallow-buried radials so no need to concern yourself with particular lenghts. You will be far better off with more and shorter wires. The attenuation along radial wires is quite high. There's no current flowing in them beyond a small fraction of a wavelength from the focal point. They may as well not be there. Wire diameter selected solely on your ideas about durability. Enamelled copper wire is fine and may be less expensive, easier to obtain than the bare stuff. Okay, I thought I heard something about this in here somewhere! So I can use insulated wire? I do have some #12 insulated solid wire - it's of the house wiring type, with a relatively hard insulation on it. I don't know if this would work or not, but it would seem to make things last a lot longer. and I wouldn't have to buy more nekkid wire. Not much point in having radials longer than 1/10th or 1/15th wavelengths in moderately good soil at the lowest frequency of interest. A little longer in poor soil. Shorter in very good soil. Moisture content and fertility is the guide. Begin with one radial and increase the number by 50% until the RECEIVED signal strength from lower frequency, stable, reliable transmitters stops increasing. Then add a few more for luck. You will probably end up with fewer radials than recommended in the handbooks. Thank you much! - Mike KB3EIA - |
#4
![]() |
|||
|
|||
![]()
Mike,
Relatively thick plastic insulated wire will do fine for shallow-buried radials. Funnily enough, they result in slightly lower input loss resistance. (If you take them out of the ground entirely, so that they behave as elevated radials, you get a very low loss of course and with strong resonance effects.) Thick plastic insulated buried radials will have slightly greater resonance effects than bare or enamelled wire which have next to none. They will also have lower attenuation in the ground. In principle they could be made somewhat longer than the equivalent bare wires. But as the length of bare wires is all wishy-washy anyway you can forget about it. Go ahead and lay it. By the way, on 160 and 80 meters, if the shape of your property is suitable, include your domestic plumbing system in the radial system. The best radial you have is the incoming metal water main pipe. ;o) At present I have a 160m inverted-L. Had it for years. The ONLY radial is the domestic incoming main water pipe. At one time there were 7 other radial wires of various lenghts around the garden but these were all disconnected when part of the garden was paved with concrete slabs. I noticed no difference in performance with the solitary but very good water-pipe radial. --- Reg. |
#5
![]() |
|||
|
|||
![]() It will be a 1/4 wave vertical for 80 meters. I have a question regarding the radials I'll be putting out. I was planning on using solid #12 copper, and was going to lay out about 500 feet total of radial. Am I better off to use fewer and longer, or shorter and more? I'm inclined toward 10 50 foot radials. I have heard opposing views on the "proper" length of radials. (I'm assuming that longer and more would be much better, but I have some practical considerations here) If you only use that much wire, go with shorter. However, you will want to put down quite a but more wire than that to get good performance. The rule of thumb I use is a minimum of 50 radials, with length at least the length of the vertical. I currently have up a similar antenna- a full size wire 80m vertical hanging from a tree fed in parallel with a 160m inverted L. So far I have about 65 radials ranging from 50' to 100' in length. The antenna works great on 80, even for far DX such as 9M6. On 160 it is fairly good, but I feel I still need more radials. Torsten N4OGW |
#6
![]() |
|||
|
|||
![]()
Mike & Reg,
I agree with Reg, mostly. A good 'rule of thumb' (for me), is put in as many radials as you can before you get sick and tired of it, then do one more. Considering that my knees give me problems, that usually works out to ~far~ less than the 'normal' number of radials. I don't exactly disagree with Reg about the domestic plumbing being used for an RF ground, but there are a lot of 'if's about that. The one 'if' that I've had a problem with is that if the plumbing happens to be shared with neighbors, you have a direct RF path into their house, and their electrical appliances, and they usually know just who's door to pound on. That may have been an isolated occurence, but something to keep in mind if the "pounding on the door" happens. What kind of wire? The 'best' wire type to use is what ever you have the most of. And the 'best' way to tell if there are enough radials is when there is no noticable improvement after adding the last few that you put in. Then put in maybe a few more just for the hell of it... 'Doc |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
Inverted ground plane antenna: compared with normal GP and low dipole. | Antenna | |||
Stupid question G5RV | Antenna | |||
QST Article: An Easy to Build, Dual-Band Collinear Antenna | Antenna | |||
Yagi / Beam antenna theory question... | Antenna |