![]() I note that any textbook I pick up shows that VSWR=(1+rho)/(1-rho) where rho is the magnitude of Gamma (Gamma=(Z-Zo)/(Z+Zo)); rho=abs(Gamma)). Now, reading TL theory texts can be confusing because of the sometimes subtle swithes to and from an assumption of lossless line (under which rho cannot exceed 1). Since VSWR is the ratio of the magnitude of the voltage at a maximum in the standing wave pattern to the magnitude of the voltage at a minimum in the standing wave pattern, if we are to infer SWR at a point on a line (if that makes sense anyway) from rho (which is a property of a point on a lossy line), isn't the formula VSWR=abs(1+rho)/abs(1-rho) correct in the general case (lossy or lossless line)? Given that rho cannot be negative (since it is the magnitude of a complex number), the general formula can be simplified to VSWR=(1+rho)/abs(1-rho). Seems to me that texts almost universally omit the absolute operation on the denominator without necessarily qualifying it with the assumption of lossless line. If VSWR=(1+rho)/abs(1-rho), then doesn't it follow that rho is not a function of VSWR (except in the lossless line case where VSWR=(1+rho)/(1-rho) and therefore rho=(VSWR-1)/(VSWR+1))? Thoughts? Owen |
#2
![]() |
|||
|
|||
![]()
Owen wrote:
I note that any textbook I pick up shows that VSWR=(1+rho)/(1-rho) where rho is the magnitude of Gamma (Gamma=(Z-Zo)/(Z+Zo)); rho=abs(Gamma)). Now, reading TL theory texts can be confusing because of the sometimes subtle swithes to and from an assumption of lossless line (under which rho cannot exceed 1). To complicate matters, roughly half the textbooks use rho instead of Gamma for the complex reflection coefficient. You've got to be careful. Since VSWR is the ratio of the magnitude of the voltage at a maximum in the standing wave pattern to the magnitude of the voltage at a minimum in the standing wave pattern, if we are to infer SWR at a point on a line (if that makes sense anyway) from rho (which is a property of a point on a lossy line), isn't the formula VSWR=abs(1+rho)/abs(1-rho) correct in the general case (lossy or lossless line)? The whole concept of VSWR gets flakey on a lossy line, and really loses its meaning. It's often analytically convenient to define a quantity at a point and call it "VSWR", although in the presence of loss it no longer means the ratio of maximum to minimum voltage on the line. Since it's lost its original meaning, it comes to mean just about anything you'd like. And the generally accepted definition then is the equation you gave in your first paragraph. That is, in the presence of loss, VSWR is something which is *defined* by that equation, rather than the equation being a means of calculating some otherwise defined property. Under the right conditions and if loss is large enough, rho can be greater than 1, in which case the VSWR as defined by the equation in the first paragraph becomes negative. Again, this is no longer a ratio of voltages along a line, but a quantity defined by an equation. If you alter the equation, you're defining a different quantity. Now, there's no reason that your "VSWR" definition isn't just as good as the conventional one (first paragraph equation). But the conventional one is pretty universally used, and yours is different, so if you're interested in communicating, it would be wise to give it a different name or at least carefully show what you mean when you use it. Given that rho cannot be negative (since it is the magnitude of a complex number), the general formula can be simplified to VSWR=(1+rho)/abs(1-rho). But it can be greater than one. See above. Seems to me that texts almost universally omit the absolute operation on the denominator without necessarily qualifying it with the assumption of lossless line. If VSWR=(1+rho)/abs(1-rho), then doesn't it follow that rho is not a function of VSWR (except in the lossless line case where VSWR=(1+rho)/(1-rho) and therefore rho=(VSWR-1)/(VSWR+1))? Rho is never a function of VSWR. VSWR is a function of rho. Unlike actual VSWR (that is, the ratio of maximum to minimum voltage along a line), the reflection coefficient can be and is rigorously and meaningfully defined at any point along a line, lossy or not. Roy Lewallen, W7EL |
#3
![]() |
|||
|
|||
![]()
Roy Lewallen wrote:
Owen wrote: I note that any textbook I pick up shows that VSWR=(1+rho)/(1-rho) where rho is the magnitude of Gamma (Gamma=(Z-Zo)/(Z+Zo)); rho=abs(Gamma)). .... property of a point on a lossy line), isn't the formula VSWR=abs(1+rho)/abs(1-rho) correct in the general case (lossy or lossless line)? The whole concept of VSWR gets flakey on a lossy line, and really loses its meaning. It's often analytically convenient to define a quantity at a point and call it "VSWR", although in the presence of loss it no longer means the ratio of maximum to minimum voltage on the line. Since Indeed. It occurs to me that if one was to try to measure VSWR (say using a slotted line with probe) on a lossy line operating at high VSWR, the best estimate would come from finding a minimum, measuring it and the adjacent maxima and calculating VSWR=(Vmax1+Vmax2)/Vmin/2 so that the measurement is biassed towards the notional VSWR at the point of the minimum (the minimum being much more sensitive to line attenuation than the maxima). it's lost its original meaning, it comes to mean just about anything you'd like. And the generally accepted definition then is the equation you gave in your first paragraph. That is, in the presence of loss, VSWR is something which is *defined* by that equation, rather than the equation being a means of calculating some otherwise defined property. Noted Under the right conditions and if loss is large enough, rho can be greater than 1, in which case the VSWR as defined by the equation in the first paragraph becomes negative. Again, this is no longer a ratio of voltages along a line, but a quantity defined by an equation. If you alter the equation, you're defining a different quantity. Now, there's no reason that your "VSWR" definition isn't just as good as the conventional one (first paragraph equation). But the conventional one is pretty universally used, and yours is different, so if you're interested in communicating, it would be wise to give it a different name or at least carefully show what you mean when you use it. Given that rho cannot be negative (since it is the magnitude of a complex number), the general formula can be simplified to VSWR=(1+rho)/abs(1-rho). But it can be greater than one. See above. Agreed. Seems to me that texts almost universally omit the absolute operation on the denominator without necessarily qualifying it with the assumption of lossless line. If VSWR=(1+rho)/abs(1-rho), then doesn't it follow that rho is not a function of VSWR (except in the lossless line case where VSWR=(1+rho)/(1-rho) and therefore rho=(VSWR-1)/(VSWR+1))? Rho is never a function of VSWR. VSWR is a function of rho. Unlike I mean't function in the sense that there is one and only one value of f(x) for x, rather than in the causual sense. actual VSWR (that is, the ratio of maximum to minimum voltage along a line), the reflection coefficient can be and is rigorously and meaningfully defined at any point along a line, lossy or not. Agreed. Thanks for your exhaustive reply Roy, it is appreciated. What I glean from this is that although Gamma and therefore rho are well defined, and both are a function of position on a line in the general case, the "accepted mathematical definition" of VSWR in terms of rho does not behave well (eg producing a negative value) in some cases and is not a good estimator of real VSWR in those cases. It seems fair to say that the reason that the "accepted mathematical definition" of VSWR does not behave well is that it depends on an assumption of a distortionless line (Xo=0). (Lossless lines are distortionless but the converse is not necessarily true). I take your point about the need to qualify a different algorithm by a different name. Thanks again. Owen |
#4
![]() |
|||
|
|||
![]() "Roy Lewallen" wrote in message ... Owen wrote: I note that any textbook I pick up shows that VSWR=(1+rho)/(1-rho) where rho is the magnitude of Gamma (Gamma=(Z-Zo)/(Z+Zo)); rho=abs(Gamma)). Now, reading TL theory texts can be confusing because of the sometimes subtle swithes to and from an assumption of lossless line (under which rho cannot exceed 1). To complicate matters, roughly half the textbooks use rho instead of Gamma for the complex reflection coefficient. You've got to be careful. Since VSWR is the ratio of the magnitude of the voltage at a maximum in the standing wave pattern to the magnitude of the voltage at a minimum in the standing wave pattern, if we are to infer SWR at a point on a line (if that makes sense anyway) from rho (which is a property of a point on a lossy line), isn't the formula VSWR=abs(1+rho)/abs(1-rho) correct in the general case (lossy or lossless line)? The whole concept of VSWR gets flakey on a lossy line, and really loses its meaning. It's often analytically convenient to define a quantity at a point and call it "VSWR", although in the presence of loss it no longer means the ratio of maximum to minimum voltage on the line. Since it's lost its original meaning, it comes to mean just about anything you'd like. And the generally accepted definition then is the equation you gave in your first paragraph. That is, in the presence of loss, VSWR is something which is *defined* by that equation, rather than the equation being a means of calculating some otherwise defined property. Under the right conditions and if loss is large enough, rho can be greater than 1, in which case the VSWR as defined by the equation in the first paragraph becomes negative. Again, this is no longer a ratio of voltages along a line, but a quantity defined by an equation. If you alter the equation, you're defining a different quantity. Now, there's no reason that your "VSWR" definition isn't just as good as the conventional one (first paragraph equation). But the conventional one is pretty universally used, and yours is different, so if you're interested in communicating, it would be wise to give it a different name or at least carefully show what you mean when you use it. Given that rho cannot be negative (since it is the magnitude of a complex number), the general formula can be simplified to VSWR=(1+rho)/abs(1-rho). But it can be greater than one. See above. Seems to me that texts almost universally omit the absolute operation on the denominator without necessarily qualifying it with the assumption of lossless line. If VSWR=(1+rho)/abs(1-rho), then doesn't it follow that rho is not a function of VSWR (except in the lossless line case where VSWR=(1+rho)/(1-rho) and therefore rho=(VSWR-1)/(VSWR+1))? Rho is never a function of VSWR. VSWR is a function of rho. Unlike actual VSWR (that is, the ratio of maximum to minimum voltage along a line), the reflection coefficient can be and is rigorously and meaningfully defined at any point along a line, lossy or not. Roy Lewallen, W7EL Good response, Roy, but concerning rho and gamma to represent reflection coefficient, I refer you to Reflections, Sec 3.1, "Prior to the 1950s rho and sigma, and sometimes 'S' were used to represent standing wave ratio. The symbol of choice to represent reflection coefficient during that era was upper case gamma. However, in 1953 the American Standards Association (now the NIST) announced in its publication ASA Y10.9-1953, that rho is to replace gamma for reflection coefficient, with SWR to represent standing wave ratio (for either voltage or current), and VSWR specifically for voltage standing wave ratio. Most of academia responded to the change, but some individuals did not. Consequently, gamma is occasionally seen representing reflection coefficent, but only rarely." Hope this clarifies any misunderstanding concerning the use of gamma for reflection coefficient. Incidentally, Roy, I recently mailed you a CD containing Laport's book, "Radio Antenna Engineering." I'm wondering if you received it, or did it go astray? Walt, W2DU |
#5
![]() |
|||
|
|||
![]()
Owen wrote:
Thanks for your exhaustive reply Roy, it is appreciated. It's time to barbecue the virtual reflection coefficient sacred cow or at least understand that it deviates from the field of optics and S-parameter analysis. -- 73, Cecil http://www.qsl.net/w5dxp ----== Posted via Newsfeeds.Com - Unlimited-Uncensored-Secure Usenet News==---- http://www.newsfeeds.com The #1 Newsgroup Service in the World! 120,000+ Newsgroups ----= East and West-Coast Server Farms - Total Privacy via Encryption =---- |
#6
![]() |
|||
|
|||
![]()
Walter Maxwell wrote:
Good response, Roy, but concerning rho and gamma to represent reflection coefficient, I refer you to Reflections, Sec 3.1, "Prior to the 1950s rho and sigma, and sometimes 'S' were used to represent standing wave ratio. The symbol of choice to represent reflection coefficient during that era was upper case gamma. However, in 1953 the American Standards Association (now the NIST) announced in its publication ASA Y10.9-1953, that rho is to replace gamma for reflection coefficient, with SWR to represent standing wave ratio (for either voltage or current), and VSWR specifically for voltage standing wave ratio. Most of academia responded to the change, but some individuals did not. Consequently, gamma is occasionally seen representing reflection coefficent, but only rarely." Most interesting. I have on my library shelf 14 texts which deal primarily or in a major way with electromagnetic waves and/or transmission lines, and two with microwave circuit design. Of those, 8 (including both microwave design texts) use Gamma 4 use rho 2 use K 2 use k If NIST's pronouncement had any effect at all, it was the opposite of what was intended -- the four texts using rho were copyrighted in 1951, 53, 63, and 65; the 8 using Gamma were copyrighted in 1960 - 2000, 6 of them after 1965. So it appears from my sampling that Gamma is becoming more, not less, prevalant. Hope this clarifies any misunderstanding concerning the use of gamma for reflection coefficient. I'm afraid it doesn't, unless my collection is very atypical. I don't think it is, because it includes many of the classics. Incidentally, Roy, I recently mailed you a CD containing Laport's book, "Radio Antenna Engineering." I'm wondering if you received it, or did it go astray? I did indeed, Walt, and please forgive me for not acknowledging your very kind and thoughtful gift more promptly. Roy Lewallen, W7EL |
#7
![]() |
|||
|
|||
![]()
Walter Maxwell wrote:
Good response, Roy, but concerning rho and gamma to represent reflection coefficient, I refer you to Reflections, Sec 3.1, "Prior to the 1950s rho and sigma, and sometimes 'S' were used to represent standing wave ratio. The symbol of choice to represent reflection coefficient during that era was upper case gamma. However, in 1953 the American Standards Association (now the NIST) announced in its publication ASA Y10.9-1953, that rho is to replace gamma for reflection coefficient, with SWR to represent standing wave ratio (for either voltage or current), and VSWR specifically for voltage standing wave ratio. Most of academia responded to the change, but some individuals did not. Consequently, gamma is occasionally seen representing reflection coefficent, but only rarely." Thanks for the information Walter. I must have a few "rare" texts that use Gamma (Gamma to mean uppercase gamma) for the voltage reflection coefficient. I wonder if the recommendation / standard to which you refer is taken up in any international standard? I do note that my ARRL Antenna Handbook (18th edition) and ARRL Handbook (2000) both use rho, however they reckon that rho=(Za-Zo*)/(Za+Zo) (where Zo* means the conjugate of Zo). They do this without derivation, and seem to be in conflict with the derivation in most texts. I suppose the derivation is buried in some article in QST and in the members only section of the ARRL website. Back to notation, accepting that the preferred pronumeral for the voltage reflection coefficient is rho, is there a pronumeral used for abs(rho)? Owen |
#8
![]() |
|||
|
|||
![]() "Owen" wrote in message ... Walter Maxwell wrote: Good response, Roy, but concerning rho and gamma to represent reflection coefficient, I refer you to Reflections, Sec 3.1, "Prior to the 1950s rho and sigma, and sometimes 'S' were used to represent standing wave ratio. The symbol of choice to represent reflection coefficient during that era was upper case gamma. However, in 1953 the American Standards Association (now the NIST) announced in its publication ASA Y10.9-1953, that rho is to replace gamma for reflection coefficient, with SWR to represent standing wave ratio (for either voltage or current), and VSWR specifically for voltage standing wave ratio. Most of academia responded to the change, but some individuals did not. Consequently, gamma is occasionally seen representing reflection coefficent, but only rarely." Thanks for the information Walter. I must have a few "rare" texts that use Gamma (Gamma to mean uppercase gamma) for the voltage reflection coefficient. I wonder if the recommendation / standard to which you refer is taken up in any international standard? I do note that my ARRL Antenna Handbook (18th edition) and ARRL Handbook (2000) both use rho, however they reckon that rho=(Za-Zo*)/(Za+Zo) (where Zo* means the conjugate of Zo). They do this without derivation, and seem to be in conflict with the derivation in most texts. I suppose the derivation is buried in some article in QST and in the members only section of the ARRL website. Back to notation, accepting that the preferred pronumeral for the voltage reflection coefficient is rho, is there a pronumeral used for abs(rho)? Owen Hi Owen, From the general use I'm familiar with, rho alone refers to the abs value, while the two vertical bars on each side of rho indicates the magnitude alone. However, following Hewlett-Packard's usage in their AP notes, in Reflections I use a bar over rho for the absolute, and rho alone for the magnitude. However, I explain the term in the book to avoid confusion. Walt, W2DU |
#9
![]() |
|||
|
|||
![]() "Owen" wrote in message ... ............................. I do note that my ARRL Antenna Handbook (18th edition) and ARRL Handbook (2000) both use rho, however they reckon that rho=(Za-Zo*)/(Za+Zo) (where Zo* means the conjugate of Zo). They do this without derivation, and seem to be in conflict with the derivation in most texts. I suppose the derivation is buried in some article in QST and in the members only section of the ARRL website. Owen, There was a big discussion about this last year, and somebody posted that the ARRL was going to eliminate the conjugate reference. Tam/WB2TT Back to notation, accepting that the preferred pronumeral for the voltage reflection coefficient is rho, is there a pronumeral used for abs(rho)? Owen |
#10
![]() |
|||
|
|||
![]()
Tam/WB2TT wrote:
There was a big discussion about this last year, and somebody posted that the ARRL was going to eliminate the conjugate reference. Ok, I take that to mean the ARRL handbooks are in error in stating rho=(Za-Zo*)/(Za+Zo) (where Zo* means the conjugate of Zo), and that they will now use rho=(Za-Zo)/(Za+Zo). Kirchoff lives! I guess we wait and see if it comes to print. Thanks Tam. Owen |