Home |
Search |
Today's Posts |
#1
![]() |
|||
|
|||
![]()
dansawyeror wrote:
All, What is the best way to base impedance measurements, by voltage and current phase or by forward and reflected power? Measurement or calculation of forward and reverse power don't give you enough information to determine impedance. There are an infinite number of impedances which result in any given set of forward and reverse powers. Likewise, voltage and current phase don't provide enough information. Again, there are an infinite number of impedances possible for any set of voltage and current phases. First I assume both methods provide the data to measure impedance. No, neither one does. Among adequate sets of measurements which will allow you to determine impedance are both magnitude and phase of both voltage and current; or the ratio of voltage and current and the difference between their phase angles; or the magnitude and angle of the reflection coefficient. It would seem that both suffer from the real effects of the taking the measurement. Measuring voltage suffers from the effects of the reflected signal, I would assume current does as well. Couplers have a built in cross talk parameter. It's much more difficult than most people realize to make accurate RF measurements. Any measurements have numerous potential sources of error. If you need accurate results, you should always measure a number of known impedances approximately equal to the measurement being questioned to verify that the system is sound. Measuring antennas brings the additional problems of coupling among the antenna, test equipment, and you; disturbances from other signals being received by the antenna; common mode currents; and properties of connecting feedlines. Roy Lewallen, W7EL |
#2
![]() |
|||
|
|||
![]()
Roy,
Thank you. Yes, I understood both magnitude and phase are required for both. The question arose after looking into the block diagram of an HP 4805a Impedance Meter. It measures voltage and current as the basis for determining impedance. My work with a vector voltmeter has been through using directional couplers and measuring forward and reflected power. My question is: Is there an inherent accuracy benefit to one measurement basis over the other? Or: Are current and voltage probes inherently easier to build and more accurate then directional couplers? - Dan Roy Lewallen wrote: dansawyeror wrote: All, What is the best way to base impedance measurements, by voltage and current phase or by forward and reflected power? Measurement or calculation of forward and reverse power don't give you enough information to determine impedance. There are an infinite number of impedances which result in any given set of forward and reverse powers. Likewise, voltage and current phase don't provide enough information. Again, there are an infinite number of impedances possible for any set of voltage and current phases. First I assume both methods provide the data to measure impedance. No, neither one does. Among adequate sets of measurements which will allow you to determine impedance are both magnitude and phase of both voltage and current; or the ratio of voltage and current and the difference between their phase angles; or the magnitude and angle of the reflection coefficient. It would seem that both suffer from the real effects of the taking the measurement. Measuring voltage suffers from the effects of the reflected signal, I would assume current does as well. Couplers have a built in cross talk parameter. It's much more difficult than most people realize to make accurate RF measurements. Any measurements have numerous potential sources of error. If you need accurate results, you should always measure a number of known impedances approximately equal to the measurement being questioned to verify that the system is sound. Measuring antennas brings the additional problems of coupling among the antenna, test equipment, and you; disturbances from other signals being received by the antenna; common mode currents; and properties of connecting feedlines. Roy Lewallen, W7EL |
#3
![]() |
|||
|
|||
![]()
On Thu, 04 May 2006 06:02:32 -0700, dansawyeror
wrote: Or: Are current and voltage probes inherently easier to build and more accurate then directional couplers? Hi Dan, Probes have the benefit of being more sensitive, but you pay a price in a far greater probablity of distorting the measurement. Unless, of course, you are only looking for an indication which is qualitative instead of quantitative. Directional couplers are quite robust, accurate, and in my experience I've never seen one that fell outside of its tolerance - except at the band edges. 73's Richard Clark, KB7QHC |
#4
![]() |
|||
|
|||
![]()
Thanks for the clarification.
The HP4805a isn't an impedance meter. It's a vector voltmeter, which measures voltage amplitude and phase. As you know, it requires external directional couplers to measure impedance. (Or you could use current measurements using current probes in addition to the voltage measurements.) When you use directional couplers with the vector voltmeter -- or with a network analyzer for that matter -- you're not measuring forward and reflected power. You're measuring forward and reflected voltage. As I mentioned in my last posting, power measurement doesn't give you enough information to determine impedance. The answer to your question is that you can't measure impedance at all using only the voltage probes of the 4805a, and you can't measure it at all by measuring forward and reverse power with directional couplers. If you want to compare using voltage *and current* probes with measuring forward and reverse *voltages* with directional couplers, the former is probably better when impedances are considerably different than 50 ohms resistive, the latter better in a near 50 ohm system. Making accurate measurements with either method is much more difficult than most people realize, and it helps to have an understanding of what you're actually measuring. Both methods have numerous sources of possible error which have to be understood and controlled. Roy Lewallen, W7EL Network dansawyeror wrote: Roy, Thank you. Yes, I understood both magnitude and phase are required for both. The question arose after looking into the block diagram of an HP 4805a Impedance Meter. It measures voltage and current as the basis for determining impedance. My work with a vector voltmeter has been through using directional couplers and measuring forward and reflected power. My question is: Is there an inherent accuracy benefit to one measurement basis over the other? Or: Are current and voltage probes inherently easier to build and more accurate then directional couplers? - Dan Roy Lewallen wrote: dansawyeror wrote: All, What is the best way to base impedance measurements, by voltage and current phase or by forward and reflected power? Measurement or calculation of forward and reverse power don't give you enough information to determine impedance. There are an infinite number of impedances which result in any given set of forward and reverse powers. Likewise, voltage and current phase don't provide enough information. Again, there are an infinite number of impedances possible for any set of voltage and current phases. First I assume both methods provide the data to measure impedance. No, neither one does. Among adequate sets of measurements which will allow you to determine impedance are both magnitude and phase of both voltage and current; or the ratio of voltage and current and the difference between their phase angles; or the magnitude and angle of the reflection coefficient. It would seem that both suffer from the real effects of the taking the measurement. Measuring voltage suffers from the effects of the reflected signal, I would assume current does as well. Couplers have a built in cross talk parameter. It's much more difficult than most people realize to make accurate RF measurements. Any measurements have numerous potential sources of error. If you need accurate results, you should always measure a number of known impedances approximately equal to the measurement being questioned to verify that the system is sound. Measuring antennas brings the additional problems of coupling among the antenna, test equipment, and you; disturbances from other signals being received by the antenna; common mode currents; and properties of connecting feedlines. Roy Lewallen, W7EL |
#5
![]() |
|||
|
|||
![]()
I'm going to take slight issue with what Roy wrote about measurement
using a directional coupler. Though it's true that the receivers could be considered to be measuring voltage, they are measuring it across a well known load (very close to 50 ohms). When we set up a system to test the performance of units we build, it's done very carefully to calibrate them for input _power_, not voltage. The usual directional coupler in a VNA is indeed a resistive bridge, with some care taken to make the known legs and the source driving it and the load observing the imbalance all 50 ohms (in a 50 ohm system). Generally a bridge whose impedance is near the impedance you want to measure is a good choice for a starting point for making accurate measurements, but it's for sure not easy to build a 10k ohm bridge at 10GHz, for example... I certainly agree with Roy that an understanding of the measurement system and the error sources is critical to getting consistently good measurements. In fact, I have several old ap notes from HP about such measurements; those ap notes may still be available through the Agilent web site, but I couldn't guarantee it. NIST (the US National Institute of Standards and Technology) has done a lot of work in characterizing errors in measurement, and they are also a source of good (but usually mathematically deeper) info. Rohde und Schwarz is another source of VNA and impedance measurement ap notes. It's such a complex subject that I really wouldn't want to even try to get into it here. And why, since it's already been dealt with nicely in freely available pubs? Cheers, Tom |
#6
![]() |
|||
|
|||
![]()
I gladly defer to Tom, who has a great deal more experience with and
knowledge of measurement devices and techniques than I. My point was that you need to know magnitude and phase of the measured quantity if you're going to determine impedance. If all you were measuring was power, you wouldn't have this information. So you must measure the voltage (or current). Roy Lewallen, W7EL K7ITM wrote: I'm going to take slight issue with what Roy wrote about measurement using a directional coupler. Though it's true that the receivers could be considered to be measuring voltage, they are measuring it across a well known load (very close to 50 ohms). When we set up a system to test the performance of units we build, it's done very carefully to calibrate them for input _power_, not voltage. The usual directional coupler in a VNA is indeed a resistive bridge, with some care taken to make the known legs and the source driving it and the load observing the imbalance all 50 ohms (in a 50 ohm system). Generally a bridge whose impedance is near the impedance you want to measure is a good choice for a starting point for making accurate measurements, but it's for sure not easy to build a 10k ohm bridge at 10GHz, for example... . . . |
#7
![]() |
|||
|
|||
![]()
On Thu, 04 May 2006 11:49:37 -0700, Roy Lewallen
wrote: Thanks for the clarification. The HP4805a isn't an impedance meter. It's a vector voltmeter, which measures voltage amplitude and phase. As you know, it requires external directional couplers to measure impedance. (Or you could use current measurements using current probes in addition to the voltage measurements.) Whoa, hold on, wait a minute or as we are now required to say in Southern Arizona, Alto Amigo! I think that Dan made a typo and meant to say "HP-8415", which is a vector impedance meter that does use a constant current r-f source and a voltage measurement to determine impedance. It's a handy instrument for probing circuits, but it has a limited higher frequency limit of 108 MHz. There is one he http://cgi.ebay.com/HP-4815A-RF-VECT...cmdZVi ewItem but without the probe, which makes it totally useless. [snip] |
#8
![]() |
|||
|
|||
![]()
It must have been something in the way that Roy worded it the first
time, but with that concise rewording, I absolutely agree! You gotta measure phase as well as amplitude if you want to determine a complex impedance. In no way should my previous post in this thread be interpreted as going against that. Cheers, Tom |
#9
![]() |
|||
|
|||
![]()
Wes Stewart wrote:
On Thu, 04 May 2006 11:49:37 -0700, Roy Lewallen wrote: Thanks for the clarification. The HP4805a isn't an impedance meter. It's a vector voltmeter, which measures voltage amplitude and phase. As you know, it requires external directional couplers to measure impedance. (Or you could use current measurements using current probes in addition to the voltage measurements.) Whoa, hold on, wait a minute or as we are now required to say in Southern Arizona, Alto Amigo! I think that Dan made a typo and meant to say "HP-8415", which is a vector impedance meter that does use a constant current r-f source and a voltage measurement to determine impedance. It's a handy instrument for probing circuits, but it has a limited higher frequency limit of 108 MHz. There is one he http://cgi.ebay.com/HP-4815A-RF-VECT...cmdZVi ewItem but without the probe, which makes it totally useless. [snip] I think the OP really means 8405 which is a VVM. I think he swapped the first two numbers. He can tell us if I'm wrong. Cheers, John |
#10
![]() |
|||
|
|||
![]()
John - KD5YI wrote:
Wes Stewart wrote: On Thu, 04 May 2006 11:49:37 -0700, Roy Lewallen wrote: . . . The HP4805a isn't an impedance meter. It's a vector voltmeter, which measures voltage amplitude and phase. . . I think the OP really means 8405 which is a VVM. I think he swapped the first two numbers. He can tell us if I'm wrong. Can't speak for the OP, but I definitely meant HP8405a, the vector voltmeter. I apologize for the transposition, and also to the OP if I made the wrong assumption about what instrument he meant. Roy Lewallen, W7EL |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|