I have an X-300 which used to work well but has been stored away for 3
years. It has now been erected well in the clear and fed with good coax. SWR is good on 70cm and very good gain but SWR is high on 2M, causing power foldback on the TX. Anyone have any idea what could have gone wrong? The internal element loks good and the centre joint OK. Richard |
#2
![]() |
|||
|
|||
![]()
Problem solved!
After removing the grub screw in the base I extracted the complete element. Checked capacitors and soldered joints - all OK. Cleaned mild tarnish off all element sections and matching sections. Took apart joints where grub screws are fitted and cleaned mating surfaces. All the grub screws were tight so had not worked loose. Also cleaned mating surface between feed and aradial/mount boss. Reassembled and re-erected. Now working fine. Seems probable that there can be come minor corrosion in joints with grub screws and og the element itself. A good clean up every two or three years would be a good move to prevent losses creeping in. 73 de Richard (Dick) G4BBH |