Hi to all,
I'm restoring my Hammarlund SP-600 JX-21 S.N. 15805. I didn't understand how operated the vernier tuning dials. The vernier tuning dials has a 0-100 scale but it seems has no connection with KHz. How can I calibrate it ? Thanks. Massimiliano IK0JJZ |
#2
![]() |
|||
|
|||
![]()
- RIGHT dial a logging scale ONLY -
Your read the frequency from the LEFT dial - You will notice that on the very top of the frequency scale it's also divided into sections: | 0 | 1 | 2 | 3 | 4 | and so on So to log a station - Read the LEFT Frequency Dial and notice the top logging scale. Then Read the RIGHT logging scale. So 10 Megacycles would be 2 - 45.5 or 245.5 You probably see the weakness in this system - not all SP-600's are calibrated exactly alike - so if you went to 245.5 on your SP-600 you would be near 10 megacycles but not exactly on it. It does work great for shortwave broadcasts - just note the time and logging scale and you will always be able to comeback to that AM station. Mine is a SP-600-JX S.N. 129 !!! - Biz WDØHCO Hi to all, I'm restoring my Hammarlund SP-600 JX-21 S.N. 15805. I didn't understand how operated the vernier tuning dials. The vernier tuning dials has a 0-100 scale but it seems has no connection with KHz. How can I calibrate it ? Thanks. Massimiliano IK0JJZ |
#3
![]() |
|||
|
|||
![]()
Thanks Biz. I understood now.
73 de Max IK0JJZ |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
FA: Argonne 50m/m Vernier Dials | Boatanchors | |||
FA: Argonne Vernier Dials (New) | Boatanchors | |||
FA: Argonne Vernier Dials (Brand New) | Boatanchors | |||
FS: Hallicrafters HT-4 Transmitter Tuning Units $30 | Boatanchors | |||
FS: Hallicrafters HT-4 Transmitter Tuning Units $30 | Boatanchors |