I can get the VFO dial to be right on at both ends but up to 5khz (one
division) off at mid dial or right from 0 to 400 and 5k off at the 500 end. I found a reccomendation about the using the lower coil peak point and it makes no difference. How much dial accuracy can I expect fron this thing? Any idea what to try to make it better? Another question I'm not sure whether to adjust the points for zero beat or peak meter deflection. |
#2
![]() |
|||
|
|||
![]()
JOHN D wrote:
I can get the VFO dial to be right on at both ends but up to 5khz (one division) off at mid dial or right from 0 to 400 and 5k off at the 500 end. I found a reccomendation about the using the lower coil peak point and it makes no difference. How much dial accuracy can I expect fron this thing? Any idea what to try to make it better? Another question I'm not sure whether to adjust the points for zero beat or peak meter deflection. You want to use the zero beat. Max meter deflection will be up/down from zero beat depending on mode. The Zero Set control on the front panel is to 'tweak' the calibration across the band where it may not line up perfectly. Utilizing it at 100kc points you should be able to get the calibration "as good as you can interpolate" on the dial. GL, Bill |
#3
![]() |
|||
|
|||
![]()
I've restored many HW-100s and HW-101s over the years.
The linearity is not all that great. If you're only off by 5 KHz at the "500" end, that's fine. Use the crystal calibrator and dial correction to line it up when you're in that end of the band. 73, Dean K5DH In article Dwjee.26170$lZ.8166@trnddc04, says... I can get the VFO dial to be right on at both ends but up to 5khz (one division) off at mid dial or right from 0 to 400 and 5k off at the 500 end. I found a reccomendation about the using the lower coil peak point and i t makes no difference. How much dial accuracy can I expect fron this thing? Any idea what to try to make it better? Another question I'm not sure whether to adjust the points for zero beat or peak meter deflection. |
#4
![]() |
|||
|
|||
![]()
It took a *lot* of back and forth with the 2 capactor adjustments, but
I got my HW-101 to 1 kHz accuracy at both ends, and no worse than that over the 500kHz range On Thu, 05 May 2005 07:00:51 GMT, "JOHN D" wrote: I can get the VFO dial to be right on at both ends but up to 5khz (one division) off at mid dial or right from 0 to 400 and 5k off at the 500 end. I found a reccomendation about the using the lower coil peak point and it makes no difference. How much dial accuracy can I expect fron this thing? Any idea what to try to make it better? Another question I'm not sure whether to adjust the points for zero beat or peak meter deflection. |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
Wanted: National MCN or SCN dial parts | Boatanchors | |||
Wanted: National MCN or SCN dial parts | Equipment | |||
Wanted: National MCN or SCN dial parts | Equipment | |||
Wanted: National MCN or SCN dial parts | Swap | |||
Hallicrafters calibration?? | Shortwave |