![]() I was aligning a Drake R-4B receiver. When aligning the receiver sensitivity and the S meter the manual states to set the RF gain to read -15 volts from TP2 (test point 2). The manual states to set the meter to S40. At -15 volts the highest I can get my meter to go is S20. I replaced every tube in the receiver except the first RF amp, and the only reason I did not replace that tube is because I don't have one of those tubes at this time. The alignment instructions for this section are on-line at; http://www.wb4hfn.com/DrakeManuals/R...ual_R4B_38.jpg The full Drake R-4b manual with schematic is on-line at; http://www.wb4hfn.com/DrakeManuals/R4B/Manual_R4B.htm Any ideas why the S meter will not go to S40? |
#2
![]() |
|||
|
|||
![]()
First check R9 and R13 both 1.5K make sure they haven't changed
Go back and touch up T6 and T7 Then check if the sens control R40 reads 1K across That should correct your full scale if your 1rst RF tube is OK. 73 Chris VE3NGW/W4 Florida Real Radios wrote: I was aligning a Drake R-4B receiver. When aligning the receiver sensitivity and the S meter the manual states to set the RF gain to read -15 volts from TP2 (test point 2). The manual states to set the meter to S40. At -15 volts the highest I can get my meter to go is S20. I replaced every tube in the receiver except the first RF amp, and the only reason I did not replace that tube is because I don't have one of those tubes at this time. The alignment instructions for this section are on-line at; http://www.wb4hfn.com/DrakeManuals/R...ual_R4B_38.jpg The full Drake R-4b manual with schematic is on-line at; http://www.wb4hfn.com/DrakeManuals/R4B/Manual_R4B.htm Any ideas why the S meter will not go to S40? |
#3
![]() |
|||
|
|||
![]()
Did you set the zero adjust to S1 with the antenna
disconnected first? In reality, on many bands there may be anywhere from s1-s9 noise level with the antenna connected. It is probably set too low. Actually you need to go back and forth between the two adjustments, and there will be some warm-up drift. Nice radio! "Real Radios" wrote in message ... I was aligning a Drake R-4B receiver. When aligning the receiver sensitivity and the S meter the manual states to set the RF gain to read -15 volts from TP2 (test point 2). The manual states to set the meter to S40. At -15 volts the highest I can get my meter to go is S20. I replaced every tube in the receiver except the first RF amp, and the only reason I did not replace that tube is because I don't have one of those tubes at this time. The alignment instructions for this section are on-line at; http://www.wb4hfn.com/DrakeManuals/R...ual_R4B_38.jpg The full Drake R-4b manual with schematic is on-line at; http://www.wb4hfn.com/DrakeManuals/R4B/Manual_R4B.htm Any ideas why the S meter will not go to S40? |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
Drake R-4b receiver sensitivity question. | Boatanchors | |||
Question on the Drake R8B Buttons | Shortwave | |||
FA Rare Drake RR-3 Receiver | Equipment | |||
FA Rare Drake RR-3 Receiver | Equipment | |||
FA Drake RR-1 Receiver and more Vintage Gear/Auction over today | Boatanchors |