I think what we read on a spectrum analyzer is dBm for the specified range. dBm/MHz is the PSD. Lets say if the signal bandwidth is occupying 500Mhz (UWB) and has a PSD of -30dBm, then what is my power in the entire channel? (-30dBm)*500 = (1microW)*500 = 500 microWatts = -3dBm So do I see the -3dBm signal level on the spectrum analyzer in the whole bandwidth? Please correct me if I am wrong. Thanks. |
#2
![]() |
|||
|
|||
![]()
A spectrum analyzer has filters with particular bandwidths. What you
see displayed is the power passed by the filter. If you have the analyzer set for a 5kHz resolution bandwidth, what you see, then, is the power in (nominally) 5kHz of spectrum. To make things accurate, you need to understand the shape of the filter, as well. In addition, you can't necessarily use that number to find power spectral density in other than a gross sense unless you know that the power is distributed more or less evenly across that piece of spectrum. That is, if you use 5kHz resolution bandwidth and the signal has 99% of its power in a 1Hz segment within that 5kHz, the signal's actual power spectral density (at its center frequency) is much higher than the indicated power per 5kHz. Many modern spectrum analyzers will display power spectral density directly for you, taking into account the filter shapes and such. Also, beware that resolution bandwidth and video bandwidth (on analyzers that have both) are not the same thing. Cheers, Tom wrote: Hello, I think what we read on a spectrum analyzer is dBm for the specified range. dBm/MHz is the PSD. Lets say if the signal bandwidth is occupying 500Mhz (UWB) and has a PSD of -30dBm, then what is my power in the entire channel? (-30dBm)*500 = (1microW)*500 = 500 microWatts = -3dBm So do I see the -3dBm signal level on the spectrum analyzer in the whole bandwidth? Please correct me if I am wrong. Thanks. |
#3
![]() |
|||
|
|||
![]()
To add to what Tom wrote,
Ordinary spectrum analyzers sweep the filter across the band of interest, so what you see is not only the power in that filter bandwidth, but the power that's at each frequency at the moment the filter is there. Movement of the filter frequency constitutes modulation of the observed signal, which in itself creates sidebands. So what you see on a spectrum analyzer is heavily influenced by the relationship between the nature of the modulation causing the bandwidth spreading and the sweep rate of the analyzer. With some broadband signals, you can get vastly different displays by changing the resolution bandwidth and sweep rate, or with different filter shapes. This is covered in detail in _Modern Spectrum Analyzer Theory and Applications_ by Morris Engelson (Artech House, 1984). I highly recommend it to anyone needing to measure and interpret complex waveforms on a spectrum analyzer. Roy Lewallen, W7EL K7ITM wrote: A spectrum analyzer has filters with particular bandwidths. What you see displayed is the power passed by the filter. If you have the analyzer set for a 5kHz resolution bandwidth, what you see, then, is the power in (nominally) 5kHz of spectrum. To make things accurate, you need to understand the shape of the filter, as well. In addition, you can't necessarily use that number to find power spectral density in other than a gross sense unless you know that the power is distributed more or less evenly across that piece of spectrum. That is, if you use 5kHz resolution bandwidth and the signal has 99% of its power in a 1Hz segment within that 5kHz, the signal's actual power spectral density (at its center frequency) is much higher than the indicated power per 5kHz. Many modern spectrum analyzers will display power spectral density directly for you, taking into account the filter shapes and such. Also, beware that resolution bandwidth and video bandwidth (on analyzers that have both) are not the same thing. Cheers, Tom wrote: Hello, I think what we read on a spectrum analyzer is dBm for the specified range. dBm/MHz is the PSD. Lets say if the signal bandwidth is occupying 500Mhz (UWB) and has a PSD of -30dBm, then what is my power in the entire channel? (-30dBm)*500 = (1microW)*500 = 500 microWatts = -3dBm So do I see the -3dBm signal level on the spectrum analyzer in the whole bandwidth? Please correct me if I am wrong. Thanks. |
#4
![]() |
|||
|
|||
![]()
Roy,
"Roy Lewallen" wrote in message ... This is covered in detail in _Modern Spectrum Analyzer Theory and Applications_ by Morris Engelson (Artech House, 1984). Does Engelson's idea of "modern" include digitizing spectrum analyzers, which have already taken over most of the mid- to high-end of test equipment and -- as with digital scopes -- will most likely soon be in all but the lowest of the low-end of instruments? Thanks, ---Joel |
#5
![]() |
|||
|
|||
![]()
Joel Kolstad wrote:
Roy, "Roy Lewallen" wrote in message ... This is covered in detail in _Modern Spectrum Analyzer Theory and Applications_ by Morris Engelson (Artech House, 1984). Does Engelson's idea of "modern" include digitizing spectrum analyzers, which have already taken over most of the mid- to high-end of test equipment and -- as with digital scopes -- will most likely soon be in all but the lowest of the low-end of instruments? No, the book was written before those came about. I fudged a little by qualifying my posting with "conventional" spectrum analyzer to exclude newer technologies, but it sounds like "conventional" is rapidly advancing to become the newer types. I got out of the SA development world just as digital techniques were beginning to develop -- my last patent (# 5,629,703), in fact, dealt with a way of reducing distortion in an A/D converter intended for use in a SA-like instrument. At that time, we were anticipating doing a conventional sweeping down-conversion, then digitizing it at a 25 MHz IF. Predictably, the digitization point has been moving toward the front of the instrument since then. I haven't followed the technology since, but I'm sure the new ones use sampling techniques combined with an FFT, which is another way of imperfectly representing what the real spectrum is like. (Actually, you can never perfectly represent the spectrum of a real waveform, because any spectrum which is finite in frequency span has to have existed for an infinite time. Any modulated waveform is way outside this category.) Sampling produces its own, different, sorts of artifacts which are different from the ones produced by sweeping, although there are some similarities. You have to be at least as careful, and maybe more so, in interpreting a sampled waveform as one which is from a swept filter. I'd be surprised if someone hasn't written an equivalent book to cover the new type instruments, although a lot of the material in Morris' books is still valid and teaches a lot about the nature of spectra. Morris was the driving force behind Tektronix's entry into the spectrum analyzer market, and the group's chief engineer and architect for a long time. He'd retired by the time I joined the group, and I only met him when he taught a couple of one-week courses based on his books. He's truly one of the experts in the field. Roy Lewallen, W7EL |
#6
![]() |
|||
|
|||
![]() Roy Lewallen wrote: Joel Kolstad wrote: Roy, "Roy Lewallen" wrote in message ... This is covered in detail in _Modern Spectrum Analyzer Theory and Applications_ by Morris Engelson (Artech House, 1984). Does Engelson's idea of "modern" include digitizing spectrum analyzers, which have already taken over most of the mid- to high-end of test equipment and -- as with digital scopes -- will most likely soon be in all but the lowest of the low-end of instruments? No, the book was written before those came about. I fudged a little by qualifying my posting with "conventional" spectrum analyzer to exclude newer technologies, but it sounds like "conventional" is rapidly advancing to become the newer types. I got out of the SA development world just as digital techniques were beginning to develop -- my last patent (# 5,629,703), in fact, dealt with a way of reducing distortion in an A/D converter intended for use in a SA-like instrument. At that time, we were anticipating doing a conventional sweeping down-conversion, then digitizing it at a 25 MHz IF. Predictably, the digitization point has been moving toward the front of the instrument since then. I haven't followed the technology since, but I'm sure the new ones use sampling techniques combined with an FFT, which is another way of imperfectly representing what the real spectrum is like. (Actually, you can never perfectly represent the spectrum of a real waveform, because any spectrum which is finite in frequency span has to have existed for an infinite time. Any modulated waveform is way outside this category.) Sampling produces its own, different, sorts of artifacts which are different from the ones produced by sweeping, although there are some similarities. You have to be at least as careful, and maybe more so, in interpreting a sampled waveform as one which is from a swept filter. I'd be surprised if someone hasn't written an equivalent book to cover the new type instruments, although a lot of the material in Morris' books is still valid and teaches a lot about the nature of spectra. Morris was the driving force behind Tektronix's entry into the spectrum analyzer market, and the group's chief engineer and architect for a long time. He'd retired by the time I joined the group, and I only met him when he taught a couple of one-week courses based on his books. He's truly one of the experts in the field. Roy Lewallen, W7EL Indeed, we've been making spectral analysis equipment using FFT techniques since the early 80's or even a little longer. I believe the HP3577 from that era uses digital IF techniques, though I never got familiar with its "guts." Things have come a very long way since then. Just as Roy says, there's a whole different set of things to understand to get accurate, meaningful measurements out of them. Even knowing what I do, I still get surprised by the instrument's response to particular signals sometimes. With respect to signals in finite bandwidths having to have existed forever, in theory that's true, but in practice, noise from sources beyond the signal of interest will always overwhelm those portions of the signal that are very far from its main power, for a huge proportion of practical signals. We'll keep pushing for higher spurious-free dynamic range and lower noise floors in the instruments, but it's probably fair to say they'll never be perfect, and signals are essentially always polluted by external noise sources as well, if only thermal noise in external resistances. I believe you can find some information on the Agilent website about factors to consider when making FFT-based spectral measurements. I probably have a pdf or two hiding somewhere in my archives covering some of this, too. Modern analyzers are backed up by some very impressive software that can help you analyze all sorts of things about modulation, signal variation with time, etc. It goes FAR beyond simple spectral displays of FFT results. One of the key features of FFT-based spectral analysis is that you don't miss as much as a swept analyzer with narrow IF does. For example, if you have a signal that keys on for a millisecond out of every second or so at 100MHz, it might indeed be radiating a broad spectrum but there's observable energy only within a few kilohertz of 100MHz. An analyzer sweeping 50-150MHz with a 1kHz resolution bandwidth will take quite a while to do its sweep, several seconds, and may very well not be "looking at" 100Mhz, or close enough to it, at the time the pulsed signal comes up to be able to see it. But an FFT-based analyzer that's sampling fast enough to capture the whole 50-150MHz band at once can easily find the 100MHz signal every time it pulses on. The FFT is, quite literally, a large bank of parallel filters/energy detectors at evenly spaced frequencies. In combination with a "windowing" function, the effective shape of those filters can be adjusted. Cheers, Tom |
#7
![]() |
|||
|
|||
![]()
Hi Roy,
That's a lot of extra detail; thanks! "Roy Lewallen" wrote in message ... Morris was the driving force behind Tektronix's entry into the spectrum analyzer market, and the group's chief engineer and architect for a long time. He'd retired by the time I joined the group, and I only met him when he taught a couple of one-week courses based on his books. He's truly one of the experts in the field. Was Dennis Rosenauer around while you were still at Tek? Last I heard (a couple of years ago), he was working on their spectrum analyzers. As you're probably aware, Tek pretty much dumped spectrum analyzer development for awhile in the '90s, and something like 3-4 years ago hired Elaine May to be the new product group manager... she having been layed off when *Agilent* decided to dump *their* spectrum analyzer development! Sheesh. Rumor had it she was trying to get a a bunch of her former co-workers from Agilent to join her up at Tek. These days Tek and Agilent seem to have realized that SAs are rather important, albeit with Agilent pursuing a more "traditional" architecture (very high frequencies, mix down to IF, digitize there) but Tektronix utilizing their high-speed ADCs from their scopes to just digitize directly and compute FFTs -- this approach limiting them to lower frequencies with noticeably less dynamic range, but giving them the advantage of being able to trigger on arbitrary masks withoug ever "missing" one. ---Joel P.S. -- Planning to visit Swaptober Fest on the 21st? |
#8
![]() |
|||
|
|||
![]() Joel Kolstad wrote: Hi Roy, That's a lot of extra detail; thanks! "Roy Lewallen" wrote in message ... Morris was the driving force behind Tektronix's entry into the spectrum analyzer market, and the group's chief engineer and architect for a long time. He'd retired by the time I joined the group, and I only met him when he taught a couple of one-week courses based on his books. He's truly one of the experts in the field. Was Dennis Rosenauer around while you were still at Tek? Last I heard (a couple of years ago), he was working on their spectrum analyzers. As you're probably aware, Tek pretty much dumped spectrum analyzer development for awhile in the '90s, and something like 3-4 years ago hired Elaine May to be the new product group manager... she having been layed off when *Agilent* decided to dump *their* spectrum analyzer development! Sheesh. .... Sheesh, indeed. Where did you hear _that_? Lots of shrinking happened back then (and not just in Agilent, for sure), but it would certainly be a stretch to say that they "dumped their spectrum analyzer development." That's a pretty gross misrepresentation of what went on. Cheers, Tom |
#9
![]() |
|||
|
|||
![]()
Hi Tom,
"K7ITM" wrote in message ps.com... Sheesh, indeed. Where did you hear _that_? Various people at Tektronix. Perhaps they were trying to portray Agilent as being somewhat more "shrunken" than they really were based on how downsized they'd just been? The new Agilent MXA series analyzers look really nice (we've had a demo). I'm glad to see that the Agilent spectrum analyzer folks realized that, if you're going to have an instrument that's based on a PC architecture, people want a *good* PC architecture to back it with -- I'm thinking of the MXA's XGA LCD, some reasonably modern CPU, etc.; it's *snappy*. Compare to some of Agilent's network analyzers... we have an N5230A that's only 9 months old, and it has a 640x480 LCD *with a dead pixel* and a whopping 500MHz CPU. Ouch! My understanding is that the current ones still have the same old LCD, but a 1.1GHz CPU now (woo hoo!) Thanks for the extra information, ---Joel |