Home |
Search |
Today's Posts |
#1
![]() |
|||
|
|||
![]()
I need to build a portable load to carry on the roof or tower to check
transmission lines, I know for intermitten use a resistor will stand alot more then its rated for so does anyone know the factor for intermitten use? |
#2
![]() |
|||
|
|||
![]()
"n4aeq" ) writes:
I need to build a portable load to carry on the roof or tower to check transmission lines, I know for intermitten use a resistor will stand alot more then its rated for so does anyone know the factor for intermitten use? But if you're just checking transmission lines, wouldn't it make sense to get by with a small dummy load, and just reduce power into the transmission lines? Michael VE2BVW |
#3
![]() |
|||
|
|||
![]()
Solder a three watt 50 ohm non-inductive resistor directly into a
PL-259 and there you are. Use a double-female barrel adaptor as a gender changer when needed. That will stand five watts momentarily, or better yet, get an SWR analyzer such as the MFJ units. They are much handier than an SWR bridge anyway. I wouldn't be without one. 73, Bill W6WRT ------------ ORIGINAL MESSAGE ------------ On 10 Nov 2006 10:50:48 -0800, "n4aeq" wrote: I need to build a portable load to carry on the roof or tower to check transmission lines, I know for intermitten use a resistor will stand alot more then its rated for so does anyone know the factor for intermitten use? |
#4
![]() |
|||
|
|||
![]()
On Fri, 10 Nov 2006 10:50:48 -0800, n4aeq wrote:
I need to build a portable load to carry on the roof or tower to check transmission lines, I know for intermitten use a resistor will stand alot more then its rated for so does anyone know the factor for intermitten use? There is no formula for calculating how much you can exceed the maximum ratings of a component. I have found that most resistors can withstand several times their maximum rating for brief periods. A lot more if you submerge them in oil. You don't want to do any high power tests while you are up the tower or on the roof. High power = high voltage = a long fall if you get a shock! 73, Ed. EI9GQ. -- Remove 'X' to reply by e-mail Linux 2.6.17 |
#5
![]() |
|||
|
|||
![]()
n4aeq wrote:
I need to build a portable load to carry on the roof or tower to check transmission lines, I know for intermitten use a resistor will stand alot more then its rated for so does anyone know the factor for intermitten use? You can connect several resistors in a series-parallel combo to get higher wattage while keeping the 50 ohm resistance. There is a limit as a non-resistive complex impedance will grow larger as you add more resistors due to stray inductance and capacitance. House the resistors in a small can and fill the can with mineral oil. This will increase the wattage rating. In fact resistors submerged in oil will handle 10-20 times their wattage rating for short periods. Paint the outside of the can black to increase radiative cooling. (Ever see a Heath Cantenna?) Hint: get 10 120 ohm 2 watt resistors, and connect them in series-parallel. (IE: 5 sets of 2 series connected resistors in parallel). This will give you a 48 ohm 20 watt resistor. With the resistors heat sinked in oil they will handle 200-400 watts for short periods. |
#6
![]() |
|||
|
|||
![]()
No one has ever gotten a shock from high power RF. Burns, yes.
Bill, W6WRT ------------ ORIGINAL MESSAGE ------------ On Sat, 11 Nov 2006 14:46:53 GMT, "Eamon Skelton" wrote: You don't want to do any high power tests while you are up the tower or on the roof. High power = high voltage = a long fall if you get a shock! |
#7
![]() |
|||
|
|||
![]()
Lemme tell you, the last (and first) time I got a burn from RF it certainly
did shock me. Would not have felt comfortable getting the burn on top of a tower. Joe vk3bki "Bill Turner" wrote in message ... No one has ever gotten a shock from high power RF. Burns, yes. Bill, W6WRT ------------ ORIGINAL MESSAGE ------------ On Sat, 11 Nov 2006 14:46:53 GMT, "Eamon Skelton" wrote: You don't want to do any high power tests while you are up the tower or on the roof. High power = high voltage = a long fall if you get a shock! |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
Question on carbon fibre fishing rod | Antenna | |||
Dummy Load experience? | Antenna | |||
F.A. 600 Watt Continuous Dummy Load - Microwave Devices 636C N | Swap | |||
Dummy Load FS | Swap | |||
non-inductive resistors: metal-film vs carbon ? | Antenna |