Home |
Search |
Today's Posts |
#1
![]() |
|||
|
|||
![]()
I've been looking at building a few vacuum-tube based projects (just for
the heck of it...and maybe use a few of the tubes I have siting around! ![]() HV(175-250 V) and either 6 or 12 for heaters Question: since I do not have the dual-voltage transformers in a single package, when wiring them into the circuit, are the 117V primaries wired in series? This SEEMS correct, but my suppositions have been wrong before! "Stupidty is the only universal capital crime; the sentence is death. There is no appeal, and execution is carried out automatically and without pity." Robert A. Heinlein "TIme Enough For Love" |
#2
![]() |
|||
|
|||
![]()
Padraigh wrote:
I've been looking at building a few vacuum-tube based projects (just for the heck of it...and maybe use a few of the tubes I have siting around! ![]() HV(175-250 V) and either 6 or 12 for heaters Question: since I do not have the dual-voltage transformers in a single package, when wiring them into the circuit, are the 117V primaries wired in series? This SEEMS correct, but my suppositions have been wrong before! "Stupidty is the only universal capital crime; the sentence is death. There is no appeal, and execution is carried out automatically and without pity." Robert A. Heinlein "TIme Enough For Love" I assume you mean using two transformers, one for the hv and one for the heaters. You must wire the primaries in PARALLEL NOT series! If you want to operate the thing on a 240v line then you need to get two identical transformers, put the secondaries in parallel and the primaries in series (total of 4 transformers in this case). |
#3
![]() |
|||
|
|||
![]()
Padraigh wrote:
I've been looking at building a few vacuum-tube based projects (just for the heck of it...and maybe use a few of the tubes I have siting around! ![]() HV(175-250 V) and either 6 or 12 for heaters Question: since I do not have the dual-voltage transformers in a single package, when wiring them into the circuit, are the 117V primaries wired in series? This SEEMS correct, but my suppositions have been wrong before! "Stupidty is the only universal capital crime; the sentence is death. There is no appeal, and execution is carried out automatically and without pity." Robert A. Heinlein "TIme Enough For Love" I assume you mean using two transformers, one for the hv and one for the heaters. You must wire the primaries in PARALLEL NOT series! If you want to operate the thing on a 240v line then you need to get two identical transformers, put the secondaries in parallel and the primaries in series (total of 4 transformers in this case). |
#4
![]() |
|||
|
|||
![]()
the primaries will be wired in parallel.
hank wd5jfr "Padraigh" wrote in message ... I've been looking at building a few vacuum-tube based projects (just for the heck of it...and maybe use a few of the tubes I have siting around! ![]() HV(175-250 V) and either 6 or 12 for heaters Question: since I do not have the dual-voltage transformers in a single package, when wiring them into the circuit, are the 117V primaries wired in series? This SEEMS correct, but my suppositions have been wrong before! "Stupidty is the only universal capital crime; the sentence is death. There is no appeal, and execution is carried out automatically and without pity." Robert A. Heinlein "TIme Enough For Love" |
#5
![]() |
|||
|
|||
![]()
the primaries will be wired in parallel.
hank wd5jfr "Padraigh" wrote in message ... I've been looking at building a few vacuum-tube based projects (just for the heck of it...and maybe use a few of the tubes I have siting around! ![]() HV(175-250 V) and either 6 or 12 for heaters Question: since I do not have the dual-voltage transformers in a single package, when wiring them into the circuit, are the 117V primaries wired in series? This SEEMS correct, but my suppositions have been wrong before! "Stupidty is the only universal capital crime; the sentence is death. There is no appeal, and execution is carried out automatically and without pity." Robert A. Heinlein "TIme Enough For Love" |
#6
![]() |
|||
|
|||
![]()
Thanks for the quick response. Yes, I plan to use 2 seperate
transformers...and will be VERY mindful of the caution needed when working with high voltages! I caused enough trouble at work last night when I added the wrong chemical (a concentrated detergent) to a chemical bath...there was this pretty purple foam flying about, though... ![]() "Stupidty is the only universal capital crime; the sentence is death. There is no appeal, and execution is carried out automatically and without pity." Robert A. Heinlein "TIme Enough For Love" |
#7
![]() |
|||
|
|||
![]()
Thanks for the quick response. Yes, I plan to use 2 seperate
transformers...and will be VERY mindful of the caution needed when working with high voltages! I caused enough trouble at work last night when I added the wrong chemical (a concentrated detergent) to a chemical bath...there was this pretty purple foam flying about, though... ![]() "Stupidty is the only universal capital crime; the sentence is death. There is no appeal, and execution is carried out automatically and without pity." Robert A. Heinlein "TIme Enough For Love" |
#8
![]() |
|||
|
|||
![]()
Bill Turner wrote:
On Sat, 22 Nov 2003 18:25:33 -0500, Kenneth %wa2mze%@%bellsouth%.%net% wrote: If you want to operate the thing on a 240v line then you need to get two identical transformers, put the secondaries in parallel and the primaries in series (total of 4 transformers in this case). __________________________________________________ _______ And get the phasing proper lest smoke spurt and fuses flash. Got that right man! |
#9
![]() |
|||
|
|||
![]()
Bill Turner wrote:
On Sat, 22 Nov 2003 18:25:33 -0500, Kenneth %wa2mze%@%bellsouth%.%net% wrote: If you want to operate the thing on a 240v line then you need to get two identical transformers, put the secondaries in parallel and the primaries in series (total of 4 transformers in this case). __________________________________________________ _______ And get the phasing proper lest smoke spurt and fuses flash. Got that right man! |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
Chicago Transformer Mod Transformer CMS-1 Specs wanted | Boatanchors | |||
isolation transformer | Equipment | |||
isolation transformer | Equipment | |||
NC 155 Receiver Transformer Data?? | Equipment | |||
NC 155 Receiver Transformer Data?? | Equipment |