Check out the article 'A Low-Cost 100 MHz Vector Network Analyzer with USB
Interface' in the July/August 2004 issue of QEX, for measuring S pars. Al, w6wqc |
#12
![]() |
|||
|
|||
![]()
On Thu, 12 Aug 2004 23:38:00 GMT, "Joe Rocci" wrote:
Paul & Steve, Steve, I'm pretty confident that the phase shift will be constant and can be calibrated out. If not, it can be made irrelevant by using two splitters, one for the forward path sample and one for the return path sample. Paul, The idea is to use the splitter 'backwards"; drive the RF into one of the splitter legs and feed the load through the common port. Assuming good directivity, any RF coming out of the other splitter leg must be reflected energy. If you put a sample of the forward energy into a scope's X input (horizontal) and a sample of the reflected energy into the Y input (vertical), you will get an elliptical display called a Lissajous pattern. If X and Y are equal in magnitude and exactly 90 deg out of phase, this will be a perfect circle. Any other phase angle will result in a elliptical pattern whose inclination angle relative to the X axis (or Y axis) is a function of the phase angle. The length of the ellipse is a function of the magnitude. This is classic stuff...look it up if you're not familiar with THanks for the explanation, but I doubt this idea has enough accuracy for determining the parameters within any acceptable degree. Neat concept, though! -- "What is now proved was once only imagin'd." - William Blake, 1793. |
#13
![]() |
|||
|
|||
![]()
Paul,
I agree. That's why I started out by saying it was a wacky idea. Things like this make you think though. Sometimes those types of musings pay off later down the road. One of my mentors once said: "A good engineer remembers every good idea he ever heard. The only thing he forgets is who he heard it from". Joe W3JDR "Paul Burridge" wrote in message ... On Thu, 12 Aug 2004 23:38:00 GMT, "Joe Rocci" wrote: Paul & Steve, Steve, I'm pretty confident that the phase shift will be constant and can be calibrated out. If not, it can be made irrelevant by using two splitters, one for the forward path sample and one for the return path sample. Paul, The idea is to use the splitter 'backwards"; drive the RF into one of the splitter legs and feed the load through the common port. Assuming good directivity, any RF coming out of the other splitter leg must be reflected energy. If you put a sample of the forward energy into a scope's X input (horizontal) and a sample of the reflected energy into the Y input (vertical), you will get an elliptical display called a Lissajous pattern. If X and Y are equal in magnitude and exactly 90 deg out of phase, this will be a perfect circle. Any other phase angle will result in a elliptical pattern whose inclination angle relative to the X axis (or Y axis) is a function of the phase angle. The length of the ellipse is a function of the magnitude. This is classic stuff...look it up if you're not familiar with THanks for the explanation, but I doubt this idea has enough accuracy for determining the parameters within any acceptable degree. Neat concept, though! -- "What is now proved was once only imagin'd." - William Blake, 1793. |
#14
![]() |
|||
|
|||
![]()
On Fri, 13 Aug 2004 12:02:26 GMT, "W3JDR" wrote:
Paul, I agree. That's why I started out by saying it was a wacky idea. Things like this make you think though. Sometimes those types of musings pay off later down the road. One of my mentors once said: "A good engineer remembers every good idea he ever heard. The only thing he forgets is who he heard it from". Too true! Well don't forget this one; there's certainly a seed of possibility there, bar a few inevitable hurdles to overcome. -- "What is now proved was once only imagin'd." - William Blake, 1793. |
#15
![]() |
|||
|
|||
![]()
"Joe Rocci" wrote in message
news:sbTSc.7003$BS3.1582@trndny04... Paul & Steve, Steve, I'm pretty confident that the phase shift will be constant and can be calibrated out. If not, it can be made irrelevant by using two splitters, one for the forward path sample and one for the return path sample. Paul, The idea is to use the splitter 'backwards"; drive the RF into one of the splitter legs and feed the load through the common port. Assuming good directivity, any RF coming out of the other splitter leg must be reflected energy. If you put a sample of the forward energy into a scope's X input (horizontal) and a sample of the reflected energy into the Y input (vertical), you will get an elliptical display called a Lissajous pattern. If X and Y are equal in magnitude and exactly 90 deg out of phase, this will be a perfect circle. Any other phase angle will result in a elliptical pattern whose inclination angle relative to the X axis (or Y axis) is a function of the phase angle. The length of the ellipse is a function of the magnitude. This is classic stuff...look it up if you're not familiar with it. Joe W3JDR You guys seem too negative. I know I was pointing out difficulties, but only to keep the limitations in mind. Actually, it ain't that wacky. It is EXACTLY how the Professional equipment does it, just with really good couplers etc... As long as the phase and magnitude can either be controlled or known and calibrated out, it should be pretty good. If you have a scope that can go to the frequency of interest, you have a really good basis for success. The one thing I couldn't get fixed in my mind is the phase considerations of using one splitter for forward sampling and one for reverse. Two things to consider a 1- As the freq gets higher, the phase of the FWD sample and REV samples get "further apart" since they can not be at exactly at the same point on the t-line, namely the load. Therefore, you have to adjust the line lengths to 'move' them to the same virtual point. Perhaps at HF this is a don't care. I'm used to doing this @ 150 MHz. 2- If you are in a region where there is a phase change with frequency in the splitter/coupler, are you sure that it is the same in both directions, or does it not work that way and will it work to increase the error rather than both of them tracking together. I just can't model this in my brain without putting some things on paper... I guess, with the scope, you can examine that and make adjustments for it by using "calibration loads" just like the calibration kits used by the pros. I still believe the Lissajous (I'm sure glad you can spell that) method is not as good as simply measuring phase shift between the two signals directly in normal scope mode. With the Lissajous, it is harder to get the magnitudes equal and then measure random angles from the "tilt" of the oval. Don't the Lissajous formulas all assume equal magnitude sine waves? You'd have to compare amplitudes in normal mode and adjust the vert gain to set them equal anyway, so why not just set the horizontal sweep speed for a 'nice' speed and then the shift is on a calibrated scale. 9 divisions for a 1/2 cycle and you have 20 degrees per cm and the little divisions are 4 and you estimate from there. This way the phase measurement is almost 100% independent of amplitude 'cuz you're looking only @ the zero crossings. I don't think you can estimate 4 degrees on a Lissajous that easily. I still wonder WHAT kind of transistors the OP wanted to measure... -- Steve N, K,9;d, c. i My email has no u's. |
#16
![]() |
|||
|
|||
![]()
On Fri, 13 Aug 2004 10:03:51 -0500, "Steve Nosko"
wrote: I still wonder WHAT kind of transistors the OP wanted to measure... Nothing toooo special: 2N5109s and that ilk. -- "What is now proved was once only imagin'd." - William Blake, 1793. |
#17
![]() |
|||
|
|||
![]()
John Miles wrote:
The fly in the ointment is that scopes typically don't have very high bandwidth (more than a few MHz) in X-Y mode. The X-axis amplifier section of even a relatively-fast analog scope like the 2467 is only rated at 3 MHz, and you'll probably get significant phase shift long before that point is reached -- jm For sure, you shouldn't use an analog scope for this, for the reason John gives. In an analog scope, both the vertical amplifiers and the vertical CRT deflection system are optimized for speed, but the horizontal aren't. Even if you use identical amplifiers for X and Y, the horizontal CRT deflection structure will limit the X bandwidth, and give you considerable phase shift well below the cutoff frequency. Modern digital scopes, on the other hand, should work equally well on the two axes. Roy Lewallen, W7EL |
#18
![]() |
|||
|
|||
![]()
Use a direction coupler for forward and reverse measurement.
Use a 2 Chan. Scope great bandwith not nessesary, it is the amplitude that is to be measured. reflection coefficient = Vreflected/Vincident = polar magn. and angle Chris Bowick Book page 104, reflection coefficient may be plotted directly in the Smith Chart, and the corresponding impedance read off the chart. Or did I missed something? "Joe Rocci" schreef in bericht news:T0eSc.4297$Kv2.4186@trndny09... Steve, A decent (not the dollar store variety) CATV splitter has directivity of about 30 dB from 5Mhz to over 500 MHZ. I think this would do the job. Joe W3JDR Steve Nosko wrote in message ... "Paul Burridge" wrote in message ... On Tue, 10 Aug 2004 01:53:44 GMT, "Joe Rocci" wrote: Here's an idea that's just whacky enough that it might work...has anyone tried it? If you have a dual-trace scope with enough bandwidth, you might be able use Lissajous patterns. The idea would be to drive the complex load through a directional coupler with fairly good directivity. A sample of the incident signal would go into the scope X input and a sample of the reflected signal would go into the Y input. With a pure reactance as a calibration load, adjust the X and Y scope gain for a perfect circle on the display. Replace the test load with a complex load, and the magnitude and inclination of the line/oval display can tell you amplitude and phase of the reflected signal, from which any other metric can be calculated. Nice idea, Joe! If it could only be made to work, you'd be a genius. -- OK Actually, this looks good as long as you have a directional coupler for the frequency of interest! Paul didn't say. (SWR Bridge, actual bridge, for lower frequencies) You'll also have to allow for the difference in location of the two samples by adjusting the line lengths to the two scope probes intil they are both at the same "distance" from the load. Judging phase shift from a circle can't be as good as simply looking at the two waveforms. The scope horiz gain can be adjusted for some nice number of divisions for each half cycle, say 9... I've got a 100MHz. dual trace storage scope, but any directional couplers around here only will be down to 130 Mhz at best... I do also have a good bridge for down to 5 MHz., (also about 1 meter worth of stretch line...so it is possible as long as the power level is within the bridge capability. -- Steve N, K,9;d, c. i My email has no u's. |
#19
![]() |
|||
|
|||
![]()
Read the whole thread....
Joe W3JDR bviel wrote in message ... Use a direction coupler for forward and reverse measurement. Use a 2 Chan. Scope great bandwith not nessesary, it is the amplitude that is to be measured. reflection coefficient = Vreflected/Vincident = polar magn. and angle Chris Bowick Book page 104, reflection coefficient may be plotted directly in the Smith Chart, and the corresponding impedance read off the chart. Or did I missed something? "Joe Rocci" schreef in bericht news:T0eSc.4297$Kv2.4186@trndny09... Steve, A decent (not the dollar store variety) CATV splitter has directivity of about 30 dB from 5Mhz to over 500 MHZ. I think this would do the job. Joe W3JDR Steve Nosko wrote in message ... "Paul Burridge" wrote in message ... On Tue, 10 Aug 2004 01:53:44 GMT, "Joe Rocci" wrote: Here's an idea that's just whacky enough that it might work...has anyone tried it? If you have a dual-trace scope with enough bandwidth, you might be able use Lissajous patterns. The idea would be to drive the complex load through a directional coupler with fairly good directivity. A sample of the incident signal would go into the scope X input and a sample of the reflected signal would go into the Y input. With a pure reactance as a calibration load, adjust the X and Y scope gain for a perfect circle on the display. Replace the test load with a complex load, and the magnitude and inclination of the line/oval display can tell you amplitude and phase of the reflected signal, from which any other metric can be calculated. Nice idea, Joe! If it could only be made to work, you'd be a genius. -- OK Actually, this looks good as long as you have a directional coupler for the frequency of interest! Paul didn't say. (SWR Bridge, actual bridge, for lower frequencies) You'll also have to allow for the difference in location of the two samples by adjusting the line lengths to the two scope probes intil they are both at the same "distance" from the load. Judging phase shift from a circle can't be as good as simply looking at the two waveforms. The scope horiz gain can be adjusted for some nice number of divisions for each half cycle, say 9... I've got a 100MHz. dual trace storage scope, but any directional couplers around here only will be down to 130 Mhz at best... I do also have a good bridge for down to 5 MHz., (also about 1 meter worth of stretch line...so it is possible as long as the power level is within the bridge capability. -- Steve N, K,9;d, c. i My email has no u's. |
#20
![]() |
|||
|
|||
![]() "bviel" wrote in message ... Use a direction coupler for forward and reverse measurement. Use a 2 Chan. Scope great bandwith not nessesary, it is the amplitude that is to be measured. reflection coefficient = Vreflected/Vincident = polar magn. and angle Chris Bowick Book page 104, reflection coefficient may be plotted directly in the Smith Chart, and the corresponding impedance read off the chart. Or did I missed something? Yup, much of what was said. You simply restated it, to some degree. We were MUCH deeper...way past the basics. The scope has to work reasonably well at the frequency of interest. They can die pretty fast abofe their useful frequency. You also have to measure *phase* between the two signals. -- Steve N, K,9;d, c. i My email has no u's. "Joe Rocci" schreef in bericht news:T0eSc.4297$Kv2.4186@trndny09... Steve, A decent (not the dollar store variety) CATV splitter has directivity of about 30 dB from 5Mhz to over 500 MHZ. I think this would do the job. Joe W3JDR Steve Nosko wrote in message ... "Paul Burridge" wrote in message ... On Tue, 10 Aug 2004 01:53:44 GMT, "Joe Rocci" wrote: Here's an idea that's just whacky enough that it might work...has anyone tried it? If you have a dual-trace scope with enough bandwidth, you might be able use Lissajous patterns. The idea would be to drive the complex load through a directional coupler with fairly good directivity. A sample of the incident signal would go into the scope X input and a sample of the reflected signal would go into the Y input. With a pure reactance as a calibration load, adjust the X and Y scope gain for a perfect circle on the display. Replace the test load with a complex load, and the magnitude and inclination of the line/oval display can tell you amplitude and phase of the reflected signal, from which any other metric can be calculated. Nice idea, Joe! If it could only be made to work, you'd be a genius. -- OK Actually, this looks good as long as you have a directional coupler for the frequency of interest! Paul didn't say. (SWR Bridge, actual bridge, for lower frequencies) You'll also have to allow for the difference in location of the two samples by adjusting the line lengths to the two scope probes intil they are both at the same "distance" from the load. Judging phase shift from a circle can't be as good as simply looking at the two waveforms. The scope horiz gain can be adjusted for some nice number of divisions for each half cycle, say 9... I've got a 100MHz. dual trace storage scope, but any directional couplers around here only will be down to 130 Mhz at best... I do also have a good bridge for down to 5 MHz., (also about 1 meter worth of stretch line...so it is possible as long as the power level is within the bridge capability. -- Steve N, K,9;d, c. i My email has no u's. |