Reply
 
LinkBack Thread Tools Search this Thread Display Modes
  #1   Report Post  
Old October 6th 04, 12:25 AM
WTP07
 
Posts: n/a
Default PRO 95 TRUNKED SYSTEM

Can anyone tell me what type of trunked system a "GE" system is? Motorola?
EDACS?

Thanks...

Randy.



  #2   Report Post  
Old October 6th 04, 02:25 AM
Gerry Wheeler
 
Posts: n/a
Default

On Tue, 05 Oct 2004 18:25:32 -0400, WTP07 wrote:

Can anyone tell me what type of trunked system a "GE" system is?
Motorola? EDACS?


Not Motorola -- they're longtime competitors.

I think GE is equivalent to EDACS, but I'm open to correction. I heard the
long story once about who developed what, and then who bought whom, and
all that. As I recall, the net result is that GE was involved in EDACS.
--
Gerry Wheeler
Naples, FL

  #3   Report Post  
Old October 6th 04, 02:59 AM
WTP07
 
Posts: n/a
Default

Thanks Gerry,

The learning curve with my "new to me" PRO 95 is pretty steep....

having a hard time with picking up the trunking end of things. I keep
getting the squacking...and very infrequently...voice! I really wish I
could find an extensive trunking tutorial...

Randy.


"Gerry Wheeler" wrote in message
news
On Tue, 05 Oct 2004 18:25:32 -0400, WTP07 wrote:

Can anyone tell me what type of trunked system a "GE" system is?
Motorola? EDACS?


Not Motorola -- they're longtime competitors.

I think GE is equivalent to EDACS, but I'm open to correction. I heard the
long story once about who developed what, and then who bought whom, and
all that. As I recall, the net result is that GE was involved in EDACS.
--
Gerry Wheeler
Naples, FL



  #4   Report Post  
Old October 6th 04, 03:59 AM
Bruce Markowitz
 
Posts: n/a
Default

You need to set the bank and the channels to ED
AND
EDACS channels must be loaded in the proper order, starting with the bank
"01" channel, "00" must be locked out
"WTP07" wrote in message
. ..
Thanks Gerry,

The learning curve with my "new to me" PRO 95 is pretty steep....

having a hard time with picking up the trunking end of things. I keep
getting the squacking...and very infrequently...voice! I really wish I
could find an extensive trunking tutorial...

Randy.


"Gerry Wheeler" wrote in message
news
On Tue, 05 Oct 2004 18:25:32 -0400, WTP07 wrote:

Can anyone tell me what type of trunked system a "GE" system is?
Motorola? EDACS?


Not Motorola -- they're longtime competitors.

I think GE is equivalent to EDACS, but I'm open to correction. I heard

the
long story once about who developed what, and then who bought whom, and
all that. As I recall, the net result is that GE was involved in EDACS.
--
Gerry Wheeler
Naples, FL





  #5   Report Post  
Old October 6th 04, 08:17 PM
Paul Hirose
 
Posts: n/a
Default

WTP07 wrote:
having a hard time with picking up the trunking end of things. I keep
getting the squacking...and very infrequently...voice! I really wish I
could find an extensive trunking tutorial...


If you tell us what department you're trying to monitor and what you
know about their freqs etc., maybe someone can help with scanner
setup. As I write this my PRO-95 is simultaneously scanning EDACS and
Motorola trunked systems, as well as multiple conventional channels.
The radio is competent, but its manual is poorly organized. That
reminds me, I should finish the critique of the PRO-95 that I started
a couple months ago.

Try putting stuff like "trunking scanner", "trunked radio", etc. into
a search engine. It should come up with some useful pages.

--

Paul Hirose
To reply by email delete INVALID from address.



  #6   Report Post  
Old October 8th 04, 04:35 AM
Paul Hirose
 
Posts: n/a
Default

WTP07 wrote:

1) I have 2 "sets" of freq's....140ish Mhz and 800ish Mhz. Does this seem
right? (these are for the London ONT cops)


The official site says they're using a "3 site, 20 channel, 800
megahertz trunking system", so I'd recommend the 800 MHz freqs.

http://police.city.london.on.ca/Tech...ioOverview.htm


3) The manual states that with EDACS systems, the channels have to be in LCN
(logical channel number) order. Is this simply in order by frequency # or
is there another way to determine the LCN?


The LCNs aren't necessarily arranged in order of frequency. If you
don't know the LCN assignments it's possible to determine them by
trial and error.


2) I seem to have 2 800 Mhz control channels (CTL-01 and CTL-02 on the
display)


If a control channel is active, the CTL-01 or CTL-02 should be
intermittently replaced by talkgroup numbers when users are talking on
the system. Do you see that?

The other freqs -- do they sound like they're trunked and part of the
same system? Park the scanner on each one for a while and listen. Are
you hearing voice? The web site says the system was designed to allow
digital encrypted voice. The PRO-95 can't handle digital voice, even
when sent "in the clear".

--

Paul Hirose
To reply by email delete INVALID from address.
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
FCC: Broadband Power Line Systems Paul Policy 0 January 10th 05 06:41 PM
Los Angeles County trunked system Paul Hirose Scanner 2 August 9th 04 10:28 PM
stuff for all hams [email protected] General 0 December 19th 03 08:31 PM
OLD motorola trunking information jack smith Scanner 1 December 12th 03 10:48 AM


All times are GMT +1. The time now is 05:49 PM.

Powered by vBulletin® Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.
Copyright ©2004-2025 RadioBanter.
The comments are property of their posters.
 

About Us

"It's about Radio"

 

Copyright © 2017