Reply
 
LinkBack Thread Tools Search this Thread Display Modes
  #1   Report Post  
Old January 16th 04, 09:35 AM
CW
 
Posts: n/a
Default


"Ron Hardin" wrote in message
...
You're most likely to blow out the radio by grounding it.


Horse****.

All the radio needs
is a counterpoise to its whip; the wall wart supplies that already,
capacitively.


There is some truth to this.

If you have a multimeter, measure the AC (not DC) voltage between
two ground stakes driven in say twenty feet apart. Usually it's
about a half a volt. The earth is alive out there.


That's why the NEC requires all grounds to be bonded togeter.



  #2   Report Post  
Old January 14th 04, 08:32 PM
RHF
 
Posts: n/a
Default

AJG,

Here is a Compilation of a few "Ground" Messages posted to the
Shortwave Listerner (SWL) Antennas and AM & FM Antennas eGroup
on YAHOO:

* The UN-Ground when your Receiver is NOT Ground Zero !
http://groups.yahoo.com/group/SWL-AM...na/message/471

* Ground Zero for your Receiver
= For the Earth of It, There Is a Ground !
http://groups.yahoo.com/group/SWL-AM...na/message/470

* Ground Confusion
http://groups.yahoo.com/group/SWL-AM...na/message/445

* The "Grounding-Point" = Ground Rods and Ground Wires ETC.
http://groups.yahoo.com/group/SWL-AM...na/message/425

* GROUNDING = A Process of Alternatives
http://groups.yahoo.com/group/SWL-AM...na/message/212

* An OutSide Ground for Better Safety and more . . .
http://groups.yahoo.com/group/SWL-AM...na/message/206

* Indoor and Ouside Antenna Grounding
http://groups.yahoo.com/group/SWL-AM...nna/message/77


iane ~ RHF
..
All are WELCOME at the "Antenna Ashram"
http://groups.yahoo.com/group/SWL-AM...na/message/502
..
..
= = = (Alan J Giddings)
= = = wrote in message . com...

Hello,

Can anyone offer me a little advice on the grouding of my SW
receivers? I have a couple old Soviet SW radios, a Sony SW77,
Sangean ATS909 and a new Degen 1102. I want to make a ground
that will work well with any of these receivers. What material
is best? Copper, Iron, Steel etc? A rod or plate? What is the
best type of cable to use as a lead-in to the receiver? Is there
an ideal length? Depending on where the radio will be the lenght
could be anything from 5ft to 30ft.

Any advice is much appreciated.

Thanks,
Alan

..
  #3   Report Post  
Old January 17th 04, 09:45 AM
RHF
 
Posts: n/a
Default

AJG,

Grounds & Grounding = Five Topics for your Consideration

FIRST - Check Your A/C Power Outlets with an A/C Outlet Analyzer
like the RadioShack # 22-141. This simple devise WARNS you of
Faulty Wiring in 3-Prong 110-125 VAC Outlets in your Household.

Detects and Indicates:
* Normal Wiring
* Bad Ground
* Open Neutral
* Reversed Hot/Neutral
* Reversed Hot/Ground
* Open Hot

Plus the newest version:
Tests for Correct Operation of Ground Fault Circuit Isolators.

NOTE: Remove this Analyzer from the packaging very carefully

SAVE: The Backing Card with the Printed Test Instructions
(These Instructions are Valuable)

IMHO: EVERY HOME OWNER SHOULD HAVE ONE OF THESE !

WHY: An external outside Earth Ground Rod with Ground Wire System
for your Radio Reception Equipment and and Antennas is Actually a
HAZARD if your Household Wiring is Bad.

TBL: SO CHECK YOUR HOUSEHOLD A/C ELECTRICAL OUTLETS FIRST [.]
NOTE: Often a Bad A/C Electrical Outlet is the Source of RFI.


SECOND - Making USE Of A GROUND When NO Other Ground Is Available.

WHY: Often this is necessary because there is not other ground
available; the Radio is being run on Batteries; a Wall Wart is
being used and the output is isolated/insulated from the A/C Ground.
This simply provides a basic External Ground Directly to the
Radio at a place designated on the Radio like a Ground Terminal
or SO-239 Jack.

WHAT: Buy a standard Heavy Duty (Appliance Type) Black Rubber
"Three Prong Plug" for use as the Ground Interface with your
Household Wiring and to create the 'external' Grounding Point.

CAUTION: Only connect the ROUND Ground (Green) Prong to a
16-18 AWG Stranded Green Colored Insulated Wire of 5-10 Feet
Length with a Slotted Terminal or Alligator Chip at the other end.
(Simply Do Not Use the two blade prongs.) Why use a Green Colored
Wire because "Green" represents Household Electrical Wiring Ground.

CONNECTION: Connect the Slotted Terminal or Alligator Clip to
the Ground Connection of the Radio like the Ground Terminal or
SO-239 Jack.


THIRD - Ground your Antenna(s) at the Antenna to Feed-in-Line
Junction (outside and the building) For Noise (RFI) Reduction
use Coax Cable as a Feed-in-Line from the Antenna to the Radio
and Equipment. This outside Ground Point becomes the "Primary"
Ground for your Antenna System.


FOURTH - For Your Personal Safety and to Protect your Radio Equipment:
* Disconnect the Antenna when the Radio is not in use and during
Electrical (T&L) Storms.
* Buy a SO-239 Connector and wire the center pin to the outer
threaded fastener. (Shorted) Connect this to your Shack's
Equipement Ground BUS if you bave one.
* When the Coax Cable is Disconnected from the Radio: Connect
the Coax Cable to the SO-239 Shorting Plug.
* When Disconnected, Keep the Coax Cable at least 18" away from
the Radio. Your Shack's Equipement Ground BUS should be at least
12"-18" away from all your equipment.
* Additionally during Electrical (T&L) Storms Un-Plug (Disconnect)
the Radios and Equipment from the A/C Wall Outlet(s).


FIFTH - HOW TO: Install the Ground ROD into the Ground:
(Eazy installation of Ground RODs)
* Dig a One to Two Foot Deep Hole 6"-9" Wide.
* Fill the Hole with Water and wait till it soaks into hole.
(If really dry, fill with more water and wait. Repeat this
process if necessary and waiting over a day and/or night is OK.)
* Now begin the Implantation of the ROD into the Ground.
* * First try simply Pushing the ROD into Ground for a few feet.
* * Use home made ROD Driver (A Two Feet piece of 1" Iron Pipe
with a Nipple on one end.) Slide it over the Top of the ROD
and use it to Tap the ROD into the Ground for a few more feet.
* * Finally use a Sledge Hammer or Heavy Object to Pound the
ROD into the Ground still using the Rod Driver over the ROD until
the Top of the ROD is level with the surounding Ground.
(Remove the ROD Driver and clean-up the surface of the ROD.)
* Attach the Ground Wires using a Heavy Duty Ground Wire Clamp
designed specifically to make this type of connection.
* Fill the Hole with a "50 / 50 Mixture" of original Soil (50%)
and the other (50%) made up of these parts of 1/2 "Bentonite"
(clay kitty litter); 1/3 Epson Salt; and 1/6 Copper Sulfate
works well 'in-the-ground' around ground rod. Water this down
and 'tamp-it-down' lightly over the next few days.


SIXTH - Your specific questions are answered in the body of your message.


iane ~ RHF
..
..
= = = (Alan J Giddings)
= = = wrote in message . com...\
RMR RMR RMR RMR RMR RMR RMR RMR RMR RMR RMR RMR RMR RMR

Hello,

Can anyone offer me a little advice on the grounding of my SW
receivers? I have a couple old Soviet SW radios, a Sony SW77,
Sangean ATS-909 and a new Degen 1102. I want to make a ground
that will work well with any of these receivers.

Q - What material is best? Copper, Iron, Steel etc? A rod or plate?

=R= The most commonly used "Earthen Grounding Devise" is a
Eight Foot (8 Ft.) Copper Clad Steel Ground Rod.

Read "HOW TO: Install the Ground ROD into the Ground:" above.

Q - What is the best type of cable to use as a lead-in to the receiver?

=R= The most common type of connector from the Ground Rod to the
Radios and Equipment is Heavy Duty #8-#10 AWG Copper Wire this can
be Solid Bare Copper Wire or Seven Stranded Insulated Copper Wire.

Q - Is there an ideal length?

=R= The Shortest and most direct route as possible.

Depending on where the radio will be the lenght could be anything
from 5 Ft to 30 Ft.

Any advice is much appreciated.

Thanks,
Alan

..

I Am Glad You Asked ~ RHF

..
  #4   Report Post  
Old January 17th 04, 07:22 PM
Rob Mills
 
Posts: n/a
Default


"RHF" wrote in message
om.
...

FIRST - Check Your A/C Power Outlets with an A/C Outlet Analyzer like

the RadioShack # 22-141. This simple devise WARNS you of Faulty Wiring in
3-Prong 110-125 VAC Outlets in your Household.

Out of curiosity I just checked RS and they do still stock these ($5.95) but
about a year ago I purchased 4 of them on a close out for .99 ea.. Yes, they
are handy . I already had one but could never find it when I needed it,
don't have that problem now that I have 5.

Ya never know at the big red R, several months ago I purchased a 7.5 watt
amplified mobile speaker for just a few bucks on a close out (should have
bought more). They now have same speaker (same model number, same store)
back on the shelf for $27.95. RM~


  #5   Report Post  
Old January 18th 04, 12:03 AM
w_tom
 
Posts: n/a
Default

Now understand that the device does not detect and does not
claim to detect earth ground. That obvious is one understands
what that $6 Radio Shack tester does. There is no simple
device to verify integrity of earth ground. And that Radio
Shack tester will only report a failed safety ground - not to
be confused with earth ground. That Radio Shack tester will
not report a good safety ground. It can only report a failed
safety ground. It, or a 3.5 digit multimeter, will detect
some safety ground problems.

This discussion is about earthing. Any wire that is 1/4
wavelength or longer is an antenna - not an earthing wire.
For 60 Hz AC electric, a long wire to earth may be an earth
ground. But this discussion is about radio frequencies and
noise. That distance to earth ground must be shorter. It is
just another reason why the incoming wire first makes a less
than 10 foot connection, either via surge protector or
hardwired, to the building's single point earth ground. As
was noted in earlier posts, using multiple (separate) grounds
can create problems both for humans and transistors. Problems
that the three light tester will never detect.

That three light tester is only a preliminary check. But
there really is no substitution for visual inspection.

Rob Mills wrote:

"RHF" wrote in message
om.
..
FIRST - Check Your A/C Power Outlets with an A/C Outlet
Analyzer like the RadioShack # 22-141. This simple devise
WARNS you of Faulty Wiring in 3-Prong 110-125 VAC Outlets
in your Household.


Out of curiosity I just checked RS and they do still stock these
($5.95) but about a year ago I purchased 4 of them on a close out
for .99 ea.. Yes, they are handy . I already had one but could
never find it when I needed it, don't have that problem now that
I have 5.
...



  #6   Report Post  
Old January 18th 04, 03:10 AM
CW
 
Posts: n/a
Default

The electric idiot strikes again.


"w_tom" wrote in message
...

(bunches of useless horse****)


  #7   Report Post  
Old January 18th 04, 01:07 PM
RHF
 
Posts: n/a
Default

= = = "CW"
= = = wrote in message ...

The electric idiot strikes again.


"w_tom" wrote in message
...

(bunches of useless horse****)



CW,

Shauuu ... You'l wake him up again.


Time to Check and Adjust my 'Inverted "CK" Antenna'
( AHaaa... Now I Am Safe )

Near Field Mode: "Tune-In-the-Truth"
(What Ever It May Be)

- - - A-n-D - - -

Far Field Mode: "Tune-Out-the-Absurd"
(I Don't Know What You Call It... But I Know It - When I Hear It !)


So Say I ~ RHF
The Inventor of the 'Inverted "CK" Antenna'

..

..
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Station Grounding ku4yp Antenna 32 September 10th 04 05:18 PM
Antenna mast grounding question Mike Ekholm Antenna 25 December 5th 03 08:26 AM
Antenna grounding. kjfj Scanner 4 September 21st 03 02:48 AM
Grounding Birderman Shortwave 7 September 6th 03 11:40 PM
Grounding question - this is wierd..... John Passaneau Antenna 17 August 31st 03 07:42 AM


All times are GMT +1. The time now is 06:37 AM.

Powered by vBulletin® Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.
Copyright ©2004-2025 RadioBanter.
The comments are property of their posters.
 

About Us

"It's about Radio"

 

Copyright © 2017